No ice made, nothing operates

Unit off due to no power

Restore power

 

Unit off due to master switch in

Switch master switch to ON

 

OFF position

 

 

Unit off due to low water level

Check water supply, filter, strainer,

 

 

float valve. Correct water supply

 

Unit off due to ice level sensors

Check/clean ice level sensors

 

(photo-electric eyes) blocked

 

 

Unit off due to scale on water level

Clean water level sensor

 

sensor

 

 

Unit off due to water temperature

Thermistor will shut down unit at

 

too high

temperatures over 110oF.

Unit operates, no ice is vended

Check for ice in the bin

If no ice, check that ice maker can

 

 

make ice

 

 

Check that machine cannot keep

 

 

up with needs

 

Check for jam up of ice in

Pull chute down and allow ice to

 

dispense chute

fall out. Return chute to its normal

 

 

place.

 

If there is ice, check that the bin

Check for power to the bin drive

 

vane rotates. if not

motor, if none, check condition of

 

 

Touch-Free ice sensor.

 

If there is power to the bin drive

Disconnect electrical power,

 

motor, but the vane does not turn

remove all ice, check mechanical

 

 

condition of ice vane. Replace if

 

 

broken.

 

 

If ice vane is mechanically sound,

 

 

check bin drive, replace if broken.

Compressor on, auger motor is off

Auger motor windings open

Replace auger motor

 

Auger motor relay does not make

Replace circuit board

 

Contactor stuck

Replace contactor

Compressor does not operate

Off due to high pressure control

Check condenser, fan motor, fan

 

open

blade, or water supply on water

 

 

cooled.

 

Contactor coil is open

Replace contactor

 

Contactor contacts do not make

Replace contactor

 

Start capacitor failed

Replace start capacitor

 

Potential relay failed

Replace relay

 

Compressor windings open

Replace compressor

 

Compressor locked

Replace compressor

 

 

 

May 2001