AGITATOR

WARNING

Electrical Shock Or Personal injury Hazard

Always turn off and unplug vacuum

cleaner before performing maintenance to the vacuum cleaner. Failure to do so

could result in electrical shock or personal injury from vacuum cleaner suddenly starting.

TO CHECK THE BRUSHES

New Brushes

Worn Brushes

Support

Bar

When brushes are worn to the level of the

base support bars, replace the agitator assembly.

SERViCiNG

TO REPLACE AGITATOR ASSEMBLY

1.Remove the floor brush from the PowerMate.

2.Remove PowerMate cover, agitator cover,

belt and agitator assembly. See "To Remove Belt" in BELTCHANGING AND AGITATOR

CLEANING.

3.Replace agitator assembly.

4.Reinstall belt, agitator cover and

PowerMate cover. See "To replace belt" in

BELTCHANGING AND AGITATOR

CLEANING.

5.Insertfloor brush into PowerMate until

floor brush locks into place.