CAUSESOLUTION

HandwheeU is hard to turn or column binds,

Saw burns or scores edges of wood in cut.

Bevel cuts are not true.

1_ Sawdust has collected on the elevating shafL

2_ Column is out of aHgnmenL

1_ Column tube is too Uoosein the column support.

2.Blade or teeth are bent or dull.

3.Blade is out of alignment.

4.Wrong blade is being used.

5.Board is warped.

6.Arm is loose or misaligned.

7.Yoke is loose on carriage.

8.Arm is out of alignment.

9.Work is being fed too fast.

1.Bevel lock lever is loose.

2.Blade is not perpendicular to table top.

3.Column tube is too loose in the column support.

4.Table top is not parallel to the arm.

5.Yoke is loose on carriage.

6.Arm is out of alignment.

1_ Remove handwheeU; clean and Uubricate the shafL

2_ See Adjusting the Column Tube in Assembly section,

1_ See Adjusting the Column Tube in Assembly section,

2.Sharpen or replace the blade. See the removal procedure in Assembly section.

3.Use blade alignment proce- dures in Adjustment section.

4.Change blade. See the removal procedure in Assembly section.

5.Replace the board.

6.See Setting the Arm Lock

V_Zheelin the Assembly section.

7.See Setting the 'YokeClamp procedure in Assembly section.

8.See Aligning Arm for Cross Cuts in Adjustments section.

9.Feed work into blade slower.

1.See Setting the Bevel Lock Lever in Assembly section.

2.See Aligning the Blade to the Table in Adjustments section.

3.See Adjusting the Column Tube in Assembly section.

4.See Leveling Table Supports and Leveling the Front Table in the Assembly section.

5.See Setting the Yoke Clamp procedure in Assembly section.

6.See Aligning Arm for Cross Cuts in Adjustments section.

_RRFTSMRN RADIAL SAW 315.220100

60

Page 60
Image 60
Sears 315.220100 See Adjusting the Column Tube in Assembly section, See Setting the Arm Lock VZheelin the Assembly section