A-2 Dip Switch Setting* With a RS-485 serial interface specification (a dealer option), DIP switches 2-7 and 2-8 are ignored.
Notes:
Changes in DIP switch settings (excluding switches 2-7 and 2-8 interface reset
signals) are recognized only when the printer power is turned on or when the
printer is reset by using the interface. If the DIP switch setting is changed after
the printer power is turned on, t he change does not take e ffect until the
printer is turned on again or is reset.
If you turn on DIP switch 2-7 or 2-8 while the printer is turned on, the printer may
be reset, depending on the signal state. DIP switches should not be changed
while the printer power is on.

Transmission Speed

Transmission Speed (BPS)-bits per second 1-7 1-8
2400 ON ON
4800 OFF ON
9600 ON OFF
19200 OFF OFF

Set 2

SW Function ON OFF
2-1 Handshaking (BUSY
condition) Receive buffer full Off line or
receive buffer full
2-2 Customer display
(DM-D) connection Connected Not c onnected
2-3~
2-4 Undefined —
2.5~
2.6 Internal use Fixed to Off
2-7* I/F pin 6 reset signal Enabled Disabled
2-8* I/F pin 25 reset signal Enabled Disabled