If problems occur ...
Error checklist
Problem | Possible cause | Possible solution |
|
|
|
No operation indication | No mains connection | Check the connections of |
|
| the mains connector |
|
|
|
| Fuse is defective | Replace the fuse |
|
|
|
No RF signal | Transmitter and receiver | Set transmitter and |
| are not on the same | receiver to the same |
| channel | channel |
|
|
|
| Transmitter is out of | Change the antenna |
| range | position |
|
|
|
RF signal available, | Transmitter is set to | Deactivate the pilot tone |
no audio signal | mono operation and the | evaluation on the receiver |
| pilot tone evaluation of |
|
| the receiver is activated |
|
|
|
|
| Receiver’s squelch | Reduce the squelch |
| threshold is adjusted too | threshold on the receiver |
| high |
|
|
|
|
Audio signal has a high | Transmitter sensitivity is | See “Connecting the |
level of background | adjusted too low or too | mixing console” on |
noise or is distorted | high | page 16 |
|
|
|
If problems occur that are not listed in the above table or if the problems cannot be solved with the proposed solutions, please contact your local Sennheiser agent for assistance.
25