Sennheiser SR 3256, SR 3254 manual If problems occur, Error checklist

Models: SR 3254 SR 3256

1 32
Download 32 pages 47.82 Kb
Page 26
Image 26
If problems occur ...

If problems occur ...

Error checklist

Problem

Possible cause

Possible solution

 

 

 

No operation indication

No mains connection

Check the connections of

 

 

the mains connector

 

 

 

 

Fuse is defective

Replace the fuse

 

 

 

No RF signal

Transmitter and receiver

Set transmitter and

 

are not on the same

receiver to the same

 

channel

channel

 

 

 

 

Transmitter is out of

Change the antenna

 

range

position

 

 

 

RF signal available,

Transmitter is set to

Deactivate the pilot tone

no audio signal

mono operation and the

evaluation on the receiver

 

pilot tone evaluation of

 

 

the receiver is activated

 

 

 

 

 

Receiver’s squelch

Reduce the squelch

 

threshold is adjusted too

threshold on the receiver

 

high

 

 

 

 

Audio signal has a high

Transmitter sensitivity is

See “Connecting the

level of background

adjusted too low or too

mixing console” on

noise or is distorted

high

page 16

 

 

 

If problems occur that are not listed in the above table or if the problems cannot be solved with the proposed solutions, please contact your local Sennheiser agent for assistance.