Setting up the transmitters

Setting up the transmitters

The SR 3254 and SR 3256 transmitters heat up during operation.

y Ventilation in fixed installations

Ensure sufficient ventilation, especially when the transmitters are mounted into a desk or chassis. Provide for a duct of sufficient size to ensure a free air flow between the trans- mitters.

ySufficient ventilation in a rack

When operating several transmitters in a rack, ensure sufficient ventilation or cooling. We recommend not stacking more than two transmitter directly one above the other, and then providing for a duct of sufficient size to ensure a free air flow between the transmitters.

Rack-mounting the transmitter without mounting the antennas to the front of the rack

￿Hook the two rack mount “ears” to the rear of the

transmitter.

￿Secure the rack mount “ears” to the left and right of the

transmitter using four recessed head screws respectively.

￿ Slide the transmitter into the 19" rack.

￿ Secure the rack mount “ears” to the rack.