Starting the scan and storing the scan result

Before starting the scan, switch all transmitters of your system off, since channels used by switched-on transmitters will not be displayed as “free channels”.

Select the “SCAN” menu.

Select “START” and confirm your selection by pressing the SET button. After the scan is completed, the number of free channels is displayed. Pressing the SET button once more will store the scan result and lock all channels that are used or subject to interference.

Releasing locked channels

Select the “SCAN” menu.

Select “CLEAR” and confirm your selection by pressing the SET button. All channels in this channel bank can now be selected again.

Multi-channel operation

For multi-channel operation, only use the free channels in a channel bank.

Before putting the transmission links into operation, we recommend perfor- ming an auto scan.

Select a channel bank on a receiver.

Scan this channel bank for free channels. If not enough free channels are available in the selected channel bank, repeat the scan with another chan- nel bank.

Apply the scan result to all other transmitters and receivers.

SENSIT

EM 100 G2

EM 100 G2

EK 100 G2

Adjusting the sensitivity (transmitters only)

Via the “SENSIT” menu, you can adjust the modulation level of the transmit- ters. This changes the transmitter’s input sensitivity.

The input sensitivity is adjusted too high when close talking distances, spea- kers with loud voices or loud music passages cause overmodulation in the transmission link. In this case, the SK 100 G2’s yellow LED (AF PEAK) will light up and the receiver’s level display for audio signal (AF) will show full deflection (see: „Modulation display of the receiving transmitter“ on page 12).

If, on the other hand, the sensitivity is adjusted too low, the transmission link will be undermodulated, which would result in a signal with high background noise.

The sensitivity is correctly adjusted when the level display for audio signal “AF” shows full deflection only during the loudest passages.

Note:

For monitoring the adjusted sensitivity, the transmitter’s level display for audio signal (AF) always indicates the audio level – even if the transmitter is muted.

32

Page 32
Image 32
Sennheiser W100 manual Multi-channel operation, Adjusting the sensitivity transmitters only, Releasing locked channels