RS-232C interface

(1) RS-232C terminal number

To set “0”

s30 @ Terminal number s A (max. 6 digits)

Default: 1

(2) RS-232C transmission form

To set “0”

s 31 @

*A

s A

* Item:

 

Selection:

Entry:

A

Transmission line form

Half duplex system

1

 

 

Full duplex system*

0

(3) RS-232C baud rate

s 32 @ *AB s A

* Item:

 

Selection:

Entry:

 

A

Always enter 0.

 

 

0

 

B

Baud rate (bps)

 

2400

3

 

 

 

 

4800

4

 

 

 

 

9600*

5

 

 

 

19200

6

(4) RS-232C start code and end code

To set “000000”

s 33 @ *ABCDEF

*A-C: Start code 000-127 (default: 002) D-F: End code 000-127 (default: 013)

s A

(5) RS-232C time out setting

s35@ Time out (1 to 255 sec.) sA

Default: 007

Key operation example

Print

s35 @

30 sA

52

Page 54
Image 54
Sharp ER-A242 instruction manual RS-232C interface, 35 @ 30 sA