70

PC control of the TV

When a programme is set, the TV can be controlled
from the PC using the RS-232C or IP. The input
signal (PC/video) can be selected, the volume can be
adjusted and various other adjustments and settings
can be made, enabling automatic programmed
playing.
Use an RS-232C serial control cable (cross type),
ETHERNET cable (commercially available) or wireless
LAN USB adapter for the connections.
NOTE
This PC control should be used by a person who is
accustomed to using PCs.

Communication conditions for IP

LAN
ETHERNET cable
(commercially available)
Connect to the TV with the following settings made for IP
on the PC.
IP protocol TCP/IP.
Host IP address Set the IP address on the TV menu.
Service None (do not select Telnet or SSH).
TCP port# Set a port number on the TV menu
(Control port).
When you set your ID and password on the TV menu, you
need to enter them as soon as you connect to the TV.
NOTE
• The connection will be cut off when there has been no
communication for 3 minutes.
View setting

IP Control setup

1Go to “HOME” > “TV Menu” > “Setup” > “View

setting” > “Network setup” > “IP Control setup”.

2[Control setting]

This function is set to enable IP Control.

3[Device name setting]

You can set up the name of this TV for displaying
on external devices.

4[Detail setting]

You can set up Login ID, Password and Control
port for using IP Control.

Communication conditions for RS-232C

RS-232C serial control cable (cross type)
(commercially available)
Set the RS-232C communications settings on the PC
to match the TV’s communications conditions. The TV’s
communications settings are as follows:
Baud rate 9,600 bps
Data length 8 bits
Parity bit None
Stop bit 1 bit
Flow control None

Communication procedure

Send the control commands from the PC via the RS-
232C connector.
The TV operates according to the received command
and sends a response message to the PC.
Do not send multiple commands at the same time. Wait
until the PC receives the OK response before sending
the next command.
Make sure to send “A” with the carriage return and
confirm that “ERR” returns before operating.

Command format

Eight ASCII codes +CR
nop
C1 C2 C3 C4 P1 P2 P3 P4

Command four digits: Command. The text of four

characters.

Parameter four digits: Parameter 0–9, blank, ?, minus

Return code (0DH): ?

Parameter

Input the parameter values, aligning left, and fill with
blank(s) for the remainder (be sure that four values are
input for the parameter).
When the input parameter is not within an adjustable
range, “ERR” returns (refer to “Response code format”).
0055
100
0009
0
When “?” is input for some commands, the present
setting value responds.
????

Response code format

Normal response Problem response
(communication error or
incorrect command)
OK ERR
Return code (0DH) Return code (0DH)

Connecting a PC