If 4 monitors are connected in a chain, reliable operation can be ensured by sending a new command only after a reply has been returned by 4th (last) monitor.
<Repeater control>

This system has a function to allow setting of multiple monitors connected in a daisy chain using a single command. This function is called repeater control.

The number of connectable monitors varies depending on the length of the cable used and the surrounding environment.

You can use Repeater control function without assigning ID numbers.

[Example]

PC

Set 1

Set 2

Set 3

Set 4

If monitors are connected as shown above, you can execute a command like “Set all monitors’ input settings to INPUT1 (DVI: DIGITAL)”.

<Repeater control command>

Repeater control is achieved by setting the FOURTH CHARACTER of the parameter to “+”.

Example:

VOLM030+ Sets volume of all monitors to 30.

In repeater control, responses are returned by all the connected monitors.*

If you want to determine that a value has been returned by a specific set, assign ID numbers to each monitor in advance.

If no response is returned, this may be because the monitor has not received (or is still processing) the command, so it is possible that new commands may not be executed even if they

are sent.

*If power is turned “OFF” by Repeater control, only the monitor closest to the PC may return a response.

Example:

(When 4 monitors are connected, and assigned ID numbers: 1 through 4) VOLM030+

WAIT OK001 OK002 OK003 OK004

Repeater control can also be used for reading settings.

Example:

VOLM???+

 

WAIT

 

10

 

 

 

 

 

 

 

001

 

 

 

 

 

 

 

 

20

 

 

 

 

002

 

 

Volume settings for all monitors are returned.

 

 

 

30

 

 

 

 

 

 

 

003

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

004

 

 

 

 

 

 

 

• If repeater control is used during ID designation (IDSL, IDLK), the ID designation is canceled.