PC Operation (Continued)
<Response format in Advanced operation >■When a command has been executed correctly
•Response when no ID number has been set
O K
Return code (0DH, 0AH)
A response is returned when execution of the pertinent command is finished.
• Response when an ID number has been set
Space (20H) |
| Return code |
O K SPC 0 0 | 1 | (0DH, 0AH) |
|
ID number of responding monitor
■When a command has not been executed correctly*
•Response when no ID number has been set
| Return code |
E R R | (0DH, 0AH) |
|
• Response when an ID number has been set
Space (20H) | Return code |
E R R SPC 0 0 1 | (0DH, 0AH) |
| |
ID number |
|
*This is returned when there is no such command, or when the command cannot be used in the current state of the monitor.
Example: When “ADJUSTMENT” is used (a command which is effective when the input mode is “ANALOG”), while video is displayed (the input mode is “VIDEO”).
*If communication has not been established for reasons like a bad connection between the PC and the monitor, nothing is returned, not even ERR.
*If no monitor has been assigned the designated ID number (e.g. if the command IDSL0002 is used, but no monitor with ID number: 2 is found), no response is returned.
E44