PROCEDURE FOR ENTERING TO I-2
When the control unit or
If not so, the oven will not operate correctly.
1) How to enter the contents of EXPRESS DEFROST
|
|
| T = STG1 + STG2 + STG3 |
|
| ||
Constants |
|
| STG = A x T + B |
of EXPRESS |
|
| STG1 = 0.20 x T + 20 Power level 50% |
DEFROST |
|
| STG2 = 0.13 x T + 30 Power level 30% |
|
|
| STG3 = 0.67 x T - 50 Power level 20% |
|
|
|
Suppose above constants are entered.
|
| " | " : Flicker / : 0.1 sec BUZZER | |
PAD ORDER |
| DISPLAY | PHONE | |
(Door close) |
|
| • |
|
SET |
|
| • |
|
SET | "NUMBER" | • |
| |
(within 2 sec.) |
|
|
|
|
#1 START | "NUMBER" | • |
| |
EXPRESS | 1 | 0.00 DEF |
| |
DEFROST |
| |||
|
|
|
| |
2,0 | 1 | 0.20 DEF | x 2 | |
|
|
| (A) |
|
MANUAL/ | 1 |
| 0 DEF |
|
REPEAT | #2 |
| (+ - B) |
|
2 | 1 | 20 DEF |
| |
POWER |
|
| DEF "POWER" | |
LEVEL | 1 |
| 20 | 100% |
|
|
| DEF | POWER |
5 | 1 |
| 20 | 50% |
MANUAL/ | 2 | 0.00 DEF |
| |
REPEAT |
|
|
|
|
1, 3 | 2 | 0.13 DEF | x 2 | |
|
|
| (A) |
|
MANUAL/ | 2 |
| 0 DEF |
|
REPEAT |
|
|
|
|
3 | 2 | 30 DEF |
| |
|
|
| (+ - B) |
|
POWER |
|
| DEF "POWER" | |
LEVEL | 2 |
| 30 | 100% |
|
|
| DEF | POWER |
3 | 2 |
| 30 | 30% |
MANUAL/ | 3 |
| 0 DEF |
|
REPEAT |
|
|
|
|
#3 5 | 3 |
| 5 DEF |
|
POWER |
|
| DEF "POWER" | |
LEVEL | 3 |
| 5 | 100% |
|
|
| DEF POWER | |
2 | 3 |
| 5 | 20% |
SET | 4 |
| • DEF |
|
SET |
|
| • |
|
#1: No key entry signal.
#2: To
#3: Ex. "CHECK" will flash and the oven will beep after 50% of EXPRESS DEFROST time has lapsed when 5 key is entered during actual cooking.
2) How to enter the memory information
Example : Suppose cooking time 5 sec. and output power 100% are entered into the memory pad 1.
PAD ORDER | DISPLAY | PHONE | |
(Door close) |
| • |
|
SET |
| • |
|
SET | "NUMBER" | • |
|
(within 2 sec.) |
|
|
|
1 | NUMBER 1 | • |
|
| 1 |
|
|
MANUAL/ | NUMBER 1 | • 0 |
|
REPEAT | 1 |
|
|
5 | NUMBER 1 | • 5 |
|
| 1 |
|
|
SET | "NUMBER" | • |
|
SET |
| • |
|
Enter the memory information into the memory pads 1 ~ 10 referring to above example. The memory information are given below.
Memory No. | Cook Time | Output Power |
1 | 5 sec. | 100% |
2 | 10 sec. | 100% |
3 | 20 sec. | 100% |
4 | 30 sec. | 100% |
5 | 40 sec. | 100% |
6 | 50 sec. | 100% |
7 | 1 min. | 100% |
8 | 1 min.15 sec. | 100% |
9 | 1 min.30 sec. | 100% |
10 | 2 min. | 100% |
0 sec. |
|
OTHER CHECKING AND CLEARING PROCE- DURE FOR
1)To check the contents of EXPRESS DEFROST.
"" : Flicker / : 0.1 sec BUZZER
PAD ORDER |
| DISPLAY | PHONE |
(Door close) |
| • |
|
|
|
| |
CHECK | "NUMBER" • | CHECK | |
|
|
|
|
EXPRESS | 1 | 0.20 DEF | CHECK |
DEFROST |
| (A) |
|
|
|
|
|
|
| DEF | CHECK |
| 1 | 20 | POWER |
|
| (+ - B) | 50% |
2 | 0.13 DEF | CHECK |
| (A) |
|
|
|
|
| DEF | CHECK |
2 | 30 | POWER |
| (+ - B) | 30% |
|
|
|
| DEF | CHECK |
3 | 5 | POWER |
|
| 20% |
|
|
|
| (Repeat) |
|
|
|
|
CHECK | • |
|
#1: No key entry signal.
22