PROCEDURE FOR ENTERING TO I-2

R-22AT

R-24AT

PROCEDURE FOR ENTERING TO I-2

When the control unit or I-2 is exchanged, re-enter the constants of EXPRESS DEFROST, the memory information and the EEPROM data, referring to the following procedures.

If not so, the oven will not operate correctly.

1) How to enter the contents of EXPRESS DEFROST

 

 

 

T = STG1 + STG2 + STG3

 

 

Constants

 

 

STG = A x T + B

of EXPRESS

 

 

STG1 = 0.20 x T + 20 Power level 50%

DEFROST

 

 

STG2 = 0.13 x T + 30 Power level 30%

 

 

 

STG3 = 0.67 x T - 50 Power level 20%

 

 

 

Suppose above constants are entered.

 

 

"

" : Flicker / : 0.1 sec BUZZER

PAD ORDER

 

DISPLAY

PHONE

(Door close)

 

 

 

SET

 

 

 

SET

"NUMBER"

 

(within 2 sec.)

 

 

 

 

#1 START

"NUMBER"

 

EXPRESS

1

0.00 DEF

 

DEFROST

 

 

 

 

 

2,0

1

0.20 DEF

x 2

 

 

 

(A)

 

MANUAL/

1

 

0 DEF

 

REPEAT

#2

 

(+ - B)

 

2

1

20 DEF

 

POWER

 

 

DEF "POWER"

LEVEL

1

 

20

100%

 

 

 

DEF

POWER

5

1

 

20

50%

MANUAL/

2

0.00 DEF

 

REPEAT

 

 

 

 

1, 3

2

0.13 DEF

x 2

 

 

 

(A)

 

MANUAL/

2

 

0 DEF

 

REPEAT

 

 

 

 

3

2

30 DEF

 

 

 

 

(+ - B)

 

POWER

 

 

DEF "POWER"

LEVEL

2

 

30

100%

 

 

 

DEF

POWER

3

2

 

30

30%

MANUAL/

3

 

0 DEF

 

REPEAT

 

 

 

 

#3 5

3

 

5 DEF

 

POWER

 

 

DEF "POWER"

LEVEL

3

 

5

100%

 

 

 

DEF POWER

2

3

 

5

20%

SET

4

 

• DEF

 

SET

 

 

 

#1: No key entry signal.

#2: To set-B, touch the MANUAL/REPEAT key.

#3: Ex. "CHECK" will flash and the oven will beep after 50% of EXPRESS DEFROST time has lapsed when 5 key is entered during actual cooking.

2) How to enter the memory information

Example : Suppose cooking time 5 sec. and output power 100% are entered into the memory pad 1.

PAD ORDER

DISPLAY

PHONE

(Door close)

 

 

SET

 

 

SET

"NUMBER"

 

(within 2 sec.)

 

 

 

1

NUMBER 1

 

 

1

 

 

MANUAL/

NUMBER 1

• 0

 

REPEAT

1

 

 

5

NUMBER 1

• 5

 

 

1

 

 

SET

"NUMBER"

 

SET

 

 

Enter the memory information into the memory pads 1 ~ 10 referring to above example. The memory information are given below.

Memory No.

Cook Time

Output Power

1

5 sec.

100%

2

10 sec.

100%

3

20 sec.

100%

4

30 sec.

100%

5

40 sec.

100%

6

50 sec.

100%

7

1 min.

100%

8

1 min.15 sec.

100%

9

1 min.30 sec.

100%

10

2 min.

100%

11-20

0 sec.

 

OTHER CHECKING AND CLEARING PROCE- DURE FOR

1)To check the contents of EXPRESS DEFROST.

"" : Flicker / OTHER CHECKING AND CLEARING PROCE- DURE FOR : 0.1 sec BUZZER

PAD ORDER

 

DISPLAY

PHONE

(Door close)

 

 

 

 

 

CHECK

"NUMBER" •

CHECK

 

 

 

 

EXPRESS

1

0.20 DEF

CHECK

DEFROST

 

(A)

 

 

 

 

 

 

 

DEF

CHECK

 

1

20

POWER

 

 

(+ - B)

50%

2

0.13 DEF

CHECK

 

(A)

 

 

 

 

 

DEF

CHECK

2

30

POWER

 

(+ - B)

30%

 

 

 

 

DEF

CHECK

3

5

POWER

 

 

20%

 

 

 

 

(Repeat)

 

 

 

 

CHECK

 

#1: No key entry signal.

22

Page 24
Image 24
Sharp R-24AT, R-22AT service manual Procedure For Entering To, Other Checking And Clearing Proce- Dure For