DESCRIPTION OF LSI
LSI(IXA222DR)
The I/O signal of the LSI(IXA222DR) is detailed in the following table.
Pin No. | Signal | I/O |
|
|
|
| Description |
|
|
|
|
|
| ||||||||
1 | VCC | IN |
| Power source voltage: GND. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| VC voltage of power source circuit input. Connected to GND. |
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
2 | VEE | IN |
| Anode (segment) of Fluorescent Display |
|
|
| ||||||||||||||
|
|
|
| Vp voltage of power source circuit input. |
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 | AVSS | IN |
| Reference voltage input terminal. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| A reference voltage applied to the A/D converter in the LSI. Connected to DC. | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 | VREF | IN |
| Reference voltage input terminal. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| A reference voltage applied to the A/D converter in the LSI. Connected to GND. | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IN |
| Terminal to switch the specification. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
7 | AN5 | IN |
| Temperature measurement input: EXHAUST THERMISTOR |
|
|
| ||||||||||||||
|
|
|
| By inputting DC voltage corresponding to the temperature detected by the thermis- | |||||||||||||||||
|
|
|
| tor, this input is converted into temperature by the A/D converter built into the LSI. | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
8 | AN4 | IN |
| Input signal which communicates the door open/close information to LSI. | |||||||||||||||||
|
|
|
| Door closed; "H" level signal (0V). |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| Door opened; "L" level signal |
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 | AN3 | - |
| Terminal not used. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
10 | AN2 | IN |
| Temperature measurement input: MAGNETRON THERMISTOR TH2. |
|
|
| ||||||||||||||
|
|
|
| By inputting DC voltage corresponding to the temperature detected by the thermis- | |||||||||||||||||
|
|
|
| tor, this input is converted into temperature by the A/D converter built into the LSI. | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
11 | AN1 | IN |
| Temperature measurement input: MAGNETRON THERMISTOR TH1. |
|
|
| ||||||||||||||
|
|
|
| By inputting DC voltage corresponding to the temperature detected by the thermis- | |||||||||||||||||
|
|
|
| tor, this input is converted into temperature by the A/D converter built into the LSI. | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12 | AN0 | - |
| Terminal not used. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
| Terminal not used. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
15 | P53 | OUT |
| Magnetron (MG1) |
|
|
|
|
|
| |||||||||||
|
|
|
| To turn on and off the cook relay. In 100% power level operation, "L" level during | |||||||||||||||||
|
|
|
| cooking; "H" level otherwise. In other power level operation (90, 80, 70, 60, 50, 40, | |||||||||||||||||
|
|
|
| 30, 20, 10 or 0%), "H" and "L" level is repeated according to power level. |
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Power level | ON | OFF | Power level |
| ON | OFF |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 100% | 48sec. | 0sec. | 40% |
| 22sec. | 26sec. |
|
|
|
|
| OFF |
|
| GND | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 90% | 44sec. | 4sec. | 30% |
| 16sec. | 32sec. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 80% | 40sec. | 8sec. | 20% |
| 12sec. | 36sec. |
|
|
|
|
|
|
| ON |
|
| |
|
|
|
| 70% | 36sec. | 12sec. | 10% |
| 8sec. | 40sec. |
|
|
|
|
| 48 sec. |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60% | 32sec. | 16sec. | 0% |
| 0sec. | 48sec. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 50% | 26sec. | 22sec. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
16 | P52 | - |
| Terminal not used. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
17 | P51 | OUT |
| Magnetron (MG2) |
|
|
|
|
|
| |||||||||||
|
|
|
| To turn on and off the cook relay. In 100% power level operation, "L" level during | |||||||||||||||||
|
|
|
| cooking; "H" level otherwise. In other power level operation (90, 80, 70, 60, 50, 40, | |||||||||||||||||
|
|
|
| 30, 20, 10 or 0%), "H" and "L" level is repeated according to power level. |
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| Power level | ON | OFF | Power level |
| ON | OFF |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 100% | 48sec. | 0sec. | 40% |
| 22sec. | 26sec. |
|
|
|
|
| OFF |
|
| GND | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
| 90% | 44sec. | 4sec. | 30% |
| 16sec. | 32sec. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 80% | 40sec. | 8sec. | 20% |
| 12sec. | 36sec. |
|
|
|
|
|
|
| ON |
|
| |
|
|
|
| 70% | 36sec. | 12sec. | 10% |
| 8sec. | 40sec. |
|
|
|
|
| 48 sec. |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| 60% | 32sec. | 16sec. | 0% |
| 0sec. | 48sec. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
| 50% | 26sec. | 22sec. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
18 | P50 | - |
| Terminal not used. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
17