Sharp R-22AT, R-24AT service manual Test Procedures, Letter, Component Test, Steps

Models: R-22AT R-24AT

1 44
Download 44 pages 40.07 Kb
Page 17
Image 17
STEPS

R-22AT

R-24AT

TEST PROCEDURES

PROCEDURE

 

 

 

LETTER

COMPONENT TEST

 

 

 

 

 

 

STEPS

OCCURRENCE

CAUSE OR CORRECTION

 

 

1

The rated AC voltage is not present at

Check supply voltage and oven power cord.

 

 

 

POWER terminal of CPU connector (CN-A).

 

 

 

 

 

 

 

 

2

The rated AC voltage is present at primary

Touch control transformer or secondary circuit defective.

 

 

 

side of touch control transformer.

Check and repair.

 

 

 

 

 

 

 

3

Fuse on the PWB is open.

Replace the fuse with new one.

 

 

 

 

(CARRY OUT 3D CHECKS BEFORE REPAIR)

 

 

 

 

 

 

NOTE: *At the time of these repairs, make a visual inspection of the varistor for burning damage and examine the transformer with tester for the presence of layer short-circuit (check primary coil resistance). If any abnormal condition is detected, replace the defective parts.

CARRY OUT 4R CHECKS.

15

Page 17
Image 17
Sharp R-22AT, R-24AT service manual Test Procedures, Letter, Component Test, Steps