Maintenance Indicators

The warning lights on the projector indicate problems inside the projector.

If a problem occurs, either the temperature warning indicator or the lamp replacement indicator will illuminate red, and the power will turn off. After the power has been turned off, follow the proce- dures given below.

Power indicator

Lamp replacement indicator

Temperature warning indicator

About the temperature warning indicator

If the temperature inside the pro- jector increases, due to blockage of the air vents, or the setting lo-

cation, “” will blink in the lower left corner of the picture. If the temperature keeps on rising, the lamp will turn off and the tem- perature warning indicator will blink, the cooling fan will run for further 90 seconds, then the power

will be shut off. After “” ap- pears, be sure to perform the fol- lowing measures.

About the lamp replacement indicator

The lamp life becomes 0%, when used for approximately 2,000 hours with “ON” in “Power Save” or when used for approxi- mately 1,500 hours with “OFF” in “Power Save” (see page 69).

When the remaining lamp life becomes

6% or less, “” will be displayed on the screen in yellow. When the percentage

becomes 0%, “” will change to “” (red), the lamp will automatically turn off and then the projector as well. At this time, the lamp replacement indicator will illu- minate in red.

If you try to turn on the projector a fourth time without replacing the lamp, the pro- jector will not turn on.

Maintenance indicator

Condition

Problem

Possible Solution

 

 

 

 

 

 

 

 

Normal

Abnormal

 

Blocked air intake

Relocate the projector to an area

Temperature

 

 

The internal

with proper ventilation.

 

 

 

 

 

 

Cooling fan break-

Take the projector to your nearest

warning

Off

Red on/

temperature is

down

Sharp Authorized Projector Dealer

 

 

 

indicator

 

Power off

abnormally high.

Internal circuit failure

or Service Center (see page 96)

 

 

 

 

Clogged air intake

for repair.

 

 

 

 

 

 

 

 

 

Red blinks/

Time to change

Remaining lamp life

Carefully replace the lamp. (See

 

Green on

becomes 6% or

page 86)

 

Red on

the lamp

 

Green

under.

Take the projector to your nearest

Lamp

 

 

blinks

 

 

 

Sharp Authorized Projector Dealer

replacement

 

 

 

when the

 

 

 

or Service Center (see page 96)

indicator

Red on/

The lamp does

Burnt-out lamp

lamp is

for repair.

 

 

active.

Power off

not illuminate.

Lamp circuit failure

Please exercise care when

 

 

 

 

 

replacing the lamp.

 

 

 

 

 

 

 

 

 

 

 

 

Securely install the filter cover.

Power

Green on/

 

The power

The filter cover, lamp

If the power indicator blinks even

Red blinks

indicator blinks

unit cover or lens

when the filter cover is securely

indicator

Red on

in red when the

installed, contact your nearest

 

cover is open.

 

 

 

projector is on.

Sharp Authorized Projector Dealer

 

 

 

 

 

 

 

 

 

or Service Center for advice.

 

 

 

 

 

 

 