95
Table 7-2 Case Size B
MICROMASTER 411 / COMBIMASTER 411
Frame size:
2 pole
4 pole
71
71
71
80
80
80
80M
90S
90S
90S
Motor Output Rating 0.37 kW
0,5 hp
0.55 kW
0,75 hp
0.75 kW
1,0 hp
1,1 kW
1,5 hp
1,5 kW
2,0 hp
Operating Input Voltage (rms) 3 AC 380 V – 480 V ± 10 %
Operating Input Frequency 47 – 63 Hz
Output Frequency
2 pole
4 pole
0 – 650 Hz
Inrush Current < 4 A
Input Current (rms) 1,6 A 2,1 A 2,8 A 4,2 A 5,8 A
Output Current (max) 1,2 A 1,6 A 2,1 A 3,0 A 4,0 A
Power Supply fuse 10 A
Power Supply Lead
cross-section 4 mm2 (max.)
Table 7-3 Case Size C
MICROMASTER 411 / COMBIMASTER 411
Frame size:
2- pole
4- pole
90L
100L
100L
100L
Motor Output Rating 2,2 kW
3,0 hp
3,0 kW
4,0 hp
Operating Input Voltage (rms) 3 AC 380 V – 480 V ± 10 %
Operating Input Frequency 47 – 63 Hz
Output Frequency
2 pole
4 pole
0 – 650 Hz
Inrush Current < 7.7 A
Input Current (rms) 7,8 A 10 A
Output Current (max) 5,9 A 7,7 A
Power Supply fuse 16 A
Power Supply Lead
cross-section 4 mm2 (max.)