Siemens A31003-S1730-U102-1-7619 user manual 7-24

Models: A31003-S1730-U102-1-7619

1 98
Download 98 pages 14.18 Kb
Page 92
Image 92

7-24

07/2010 DAKS OScAR-Pro-TT Dataimport-Tool, User Manual

Field name

 

Keyword

Value range

Dflt. val-

Description

 

 

 

 

ue

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit 15: Active number signifies characters appended to ID

 

 

 

 

 

+

Bit 4 may not be set.

 

 

 

 

 

+

Bits 6 and 7 may only be set in combination with

 

 

 

 

 

 

bits 0 and 1.

 

 

 

 

 

Other Call Profile pa-

iExProperties

-

0

Bitmask of the other Call Profile parameters:

rameters

 

 

 

 

Bit 00: assignment of most recent announcements before the

 

 

 

 

 

 

dial-up

 

 

 

 

 

Bit 01:

<reserved>

 

 

 

 

 

Bit 02:

Confirmation callback after setting the active number.

 

 

 

 

 

Display parameters

iDispProps

see Section

0

Bit mask of the display texts, display numbers, and DTMF message

 

 

 

7.5.8, „Coding

 

 

 

 

 

 

of iDispProps“

 

 

 

 

 

 

 

 

Call acceptance code

sPickUpCode

4 characters

<empty>

Call acceptance code of the Call Profile.

Max. no. of parallel ac-

iNoOfChannels

1..99

1

The max. number of concurrent access to this profile.

cess

 

 

 

 

 

 

 

 

 

 

 

Parameters if authori-

CallScr_Action

s. description

0

The response of the system if the authorization is insufficient:

zation is insufficient

 

 

 

0:

disconnect caller

 

 

 

 

 

1:

play back announcement

 

 

 

 

 

2:

dial subscriber

 

 

 

 

 

Ident. of announce-

CallScr_Msg

-1,

-1

The identifier of the announcement if the authorization is insuffi-

ment if authorization is

 

valid ident.

 

cient.

If CallScr_Action is set to 1, this value may not be

insufficient

 

 

 

 

+

 

 

 

 

 

 

-1.

 

 

 

 

 

Ident. of subs. if au-

CallScr_Subs

-1,

-1

The identifier of the subscriber to be called if the authorization is in-

thorization is insuffi-

 

valid ident.

 

sufficient.

If CallScr_Action is set to 2, this value may not be

cient

 

 

 

 

+

 

 

 

 

 

 

-1.

 

 

 

 

 

Ident. of the info mes-

iMsg_Pervious

-1,

-1

The identifier of the information message played before the dial-up

sage played before

 

valid ident.

 

phases.

 

the dial-up.

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 7-8

Data fields of the “Call Profile“ table

 

 

 

Description of INI files

Table fields

Page 92
Image 92
Siemens A31003-S1730-U102-1-7619 user manual 7-24