Configuration

zScheduled Recording

Determine the recording condition: STOP, all day, schedule 1 or schedule 2 from the recording schedule table for all days from Monday to Sunday.

zRecording by Alarm

Configure "Alarm input setting" first. Then select the recording format:

Record source: choose JPEG or MPEG4 format

Record frame

Set the number of images to be recorded immediately after an alarm occurs. Images of the moment when an alarm occurs are not included.

1, 2, 5, 10, 30 and 60 frames can be selected if JPEG format selected. No need for MPEG4 format.

Recording cycle

Set a time interval for alarm recording 1, 2, 5, 10, 30, 60, 90, 120 s can be selected for JPEG format. No need for MPEG4 format.

Recording time:

If MPEG4 selected, please set the recording time to 2, 5, or 10 s.

zRecording by Motion

Perform "Motion Detection Setting" first.

All the other settings are same as recording by alarm as above.

zRecording by Network loss

Select network recording. After network loss, the network camera automatically stores images based on your settings.