Commissioning

7.3 Notes on operation

7.3.3Removable hard disks

The removable disk racks can also be hot swapped in connection to RAID1.

Replacing a hard disk

Caution

Hard drives may only be swapped out of the removable frames when the disks are inactive and the device status displays are off.

How to remove the hard disk drive:

1.Establish which hard disk drive of the RAID controller was reported as faulty (hard disk drive to channel 1 or 2).











(1)Power LED

voltage supply available

(2)HDD activity display

This display is always off. Please note the activity display HARDDISK

(3) on the front of the device.

The following table details the layout of the removable frames in the device according to the RAID system reports:

RAID BIOS

RAID Software

SATA interface

Installation location

Port 0

Device Port 0

SATA1

(4) Removable frame 1

Port 2

Device Port 2

SATA3

(5) Removable frame 2

You will find information regarding the reconfiguration of the RAID association in the next section.

1.Set the key switch to the "OPEN" position.

2.Push up the bezel of the hard disk cartridge.

3.Remove the hard disk cartridge.

Notes on operation

Notice

To ensure reliable operation of the devices in a removable disk rack, you need to interlock the hard disk cartridge with the disk rack.