![](/images/new-backgrounds/1122794/12279495x1.webp)
PROFIBUS Interface Center | SPC3 |
|
|
| |||
|
|
|
|
8.5 Timing Characteristics
The following is generally applicable: All signals beginning with ‘X’ are ‘low active’. All signal runtimes are based on the capacitive loads specified in the table above.
8.5.1 SYS Bus Interface
Clock Pulse:
No. | Parameter | MIN | MAX | Unit |
|
|
|
|
|
|
|
|
|
|
| Clock pulse 48 Mhz : |
|
|
|
1 | Clock High Time | 6.25 | 14.6 | ns |
2 | Clock Low Time | 6.25 | 14.6 | ns |
3 | Rise Time |
| 4 | ns |
4 | Fall Time |
| 4 | ns |
Clock Pulse Timing:
| TCLH |
| 1 |
CLK | 2,4V |
| 0,6V |
| 3 |
TCLL
2
4
Distortions in the clock pulse signal are permitted up to a ratio of 40:60. At a threshold of 1.5 or 3.5 V:
Interrupts:
No. | Parameter | MIN | MAX | Unit |
|
|
|
|
|
|
|
|
|
|
1 | Interrupt Inactive Time (for EOI_Timebase = 0) | 1 | 1 | μs |
|
|
|
|
|
| Interrupt Inactive Time | 1 | 1 | ms |
|
|
|
|
|
X/INT
EOI
1
After acknowledging an interrupt with EO1, a min. of 1 us or 1 ms is expected in SPC3 before a new interrupt is output.
Page 46 | V1.3 | SPC3 Hardware Description |
2003/04 |
| Copyright (C) Siemens AG 2003. All rights reserved. |