Siemens SPC3 Timing Characteristics, SYS Bus Interface, Clock pulse 48 Mhz, Clock Pulse Timing

Models: SPC3

1 68
Download 68 pages 15.75 Kb
Page 48
Image 48

PROFIBUS Interface Center

SPC3

 

 

 

 

 

 

 

8.5 Timing Characteristics

The following is generally applicable: All signals beginning with ‘X’ are ‘low active’. All signal runtimes are based on the capacitive loads specified in the table above.

8.5.1 SYS Bus Interface

Clock Pulse:

No.

Parameter

MIN

MAX

Unit

 

 

 

 

 

 

 

 

 

 

 

Clock pulse 48 Mhz :

 

 

 

1

Clock High Time

6.25

14.6

ns

2

Clock Low Time

6.25

14.6

ns

3

Rise Time

 

4

ns

4

Fall Time

 

4

ns

Clock Pulse Timing:

 

TCLH

 

1

CLK

2,4V

 

0,6V

 

3

TCLL

2

4

Distortions in the clock pulse signal are permitted up to a ratio of 40:60. At a threshold of 1.5 or 3.5 V:

Interrupts:

No.

Parameter

MIN

MAX

Unit

 

 

 

 

 

 

 

 

 

 

1

Interrupt Inactive Time (for EOI_Timebase = 0)

1

1

μs

 

 

 

 

 

 

Interrupt Inactive Time

1

1

ms

 

 

 

 

 

X/INT

EOI

1

After acknowledging an interrupt with EO1, a min. of 1 us or 1 ms is expected in SPC3 before a new interrupt is output.

Page 46

V1.3

SPC3 Hardware Description

2003/04

 

Copyright (C) Siemens AG 2003. All rights reserved.

Page 48
Image 48