8.5.3 Timing in the Asynchronous Intel Mode (X86 Mode) :

In 80X86 operation, SPC3 acts like memory with ready logic. The access times depend on the type of accesses.

The request for an access to SPC3 is generated from the negative edge of the read signal or the positive edge of the write signal.

SPC3 generates the Ready signal synchronously to the fed in pulse. The Ready signal is reset when the read signal or write signal is deactivated. The data bus is switched to the Tristate with XRD = 1.

No.

 

AMI-Vers.

ST-Vers.

 

 

 

 

 

Parameter

Min

Max

Min

Max

 

 

 

 

 

Unit

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

Address-Setuptime to RXD or XWR XRD to Data valid (Zugriff auf RAM)

XRD to Data valid (Zugriff auf die Register)

Address (AB10..0) Holdtime after XRD or XWR XCS Setuptime to XRD or XWR XRD-Puls-Width

Data Holdtime after XRD

Read/Write-Inactive-Time

XCS Holdtime after XRD or XWR XRD/XWR to XRDY (Normal Ready) XRD/XWR to XRDY (Early Ready) XREADY-Holdtime after XRD or XWR Data Setuptime to XWR

Data Holdtime after XWR XWR-Pulse-Width * XRD, XWR Cycletime last XRD ￿ to XCS ￿ XCS ￿ to next XWR ￿

XWR ￿ to next XWR ￿ (XCS don’t care)

0

0

- 5

6T – 10

(115)

2

10

0

4T + 5

3T + 5

4.3

10

10

4T

6T

4T + 10

2T + 10

6T

4T+5

(88,3)

4T+18

(101,3)

6

5T+ 14

4T+ 14

12.8

0

0

-5

6T 10

(115)

3.1

10

0

6

10

10

4T

6T

4T + 10

2T + 10

6T

3T+42.5

(105)

4T+20.2

(103,5)

10.2

5T + 16

4T + 12

22

ns ns

ns

ns ns ns

ns ns ns ns ns ns ns ns ns ns ns ns ns

Explanations:

 

T

=

Clock pulse cycle (48MHz)

TBD

=

to be defined

(1

=

Access to the RAM

 

(2

=

Access to the registers/latches

 

(3

=

For T = 48 MHz

 

SPC3 Hardware Description

V1.3

Page 49

Copyright (C) Siemens AG 2003 All rights reserved.

 

2003/04

Page 51
Image 51
Siemens SPC3 manual Timing in the Asynchronous Intel Mode X86 Mode, ST-Vers, Parameter Min Max