Siemens SPC3 manual Application with the 80 C

Models: SPC3

1 68
Download 68 pages 15.75 Kb
Page 43
Image 43

 

 

 

 

 

 

SPC3

 

 

PROFIBUS Interface Center

7.1.4 Application with the 80 C 32

 

 

 

 

 

 

 

 

 

 

 

 

5

CLK

SPC3

 

 

 

 

 

 

48 MHz

 

 

 

 

 

 

 

 

 

 

M

 

1K

8

XINT/MOT

CLK2

7

 

 

 

 

Px.x

36

13

 

 

 

uC

 

 

RESET

 

XHOLDT.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

14

 

 

 

 

P5

 

3k3

XCS

 

XREADY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

 

 

 

 

10

 

 

 

 

P5

 

3k3

MODE

 

AB 10

1K

M

 

 

 

 

 

 

 

 

 

ALE

24

 

 

 

 

9

 

INT0/1

 

uC

 

 

ALE

 

X/INT

 

uC

 

 

 

 

 

 

XWR

 

2

 

 

 

 

 

 

uC

 

 

XWR

 

 

 

 

 

 

 

XRD

 

4

 

 

 

 

 

 

uC

 

 

XRD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34

 

 

 

 

33

 

 

 

 

P5

 

3k3

XTEST0

 

XCTS

 

1K

 

 

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

P5

 

3k3

XTEST1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

RXD

30

 

RXD

 

 

 

5V or

DIVIDER

 

 

RS485

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

 

RTS

 

 

 

GND

 

 

 

 

RTS

 

RS485

 

 

AB8

 

44

 

 

 

 

26

 

TXD

 

 

 

0

 

 

TXD

 

RS485

 

 

 

 

 

 

 

 

 

 

 

 

AB9

 

43

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AB10

 

41

2

 

 

0

11

 

ADB0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AB11

 

40

3

 

 

1

12

 

ADB1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AB12

1

37

4

 

 

2

15

 

ADB2

 

 

 

AB13

 

42

5

 

 

3

16

 

ADB3

 

 

 

 

 

 

AB

 

DB 4

 

 

 

 

 

 

AB14

 

32

6

 

19

 

ADB4

 

 

 

 

 

 

 

 

 

 

 

 

 

ADB(8:15)

AB15

 

31

7

 

 

5

20

 

ADB5

 

 

 

 

 

 

 

 

 

 

 

uC

M

 

1K

29

8

 

 

6

21

 

ADB6

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

 

 

7

22

 

ADB7

 

 

M

 

1K

9

 

 

 

DB(0:7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

uC

The pull up / pull down resistances in the drawing above are only relevant for a in circuit tester.The internal chip select logic is activated when the address pins A 11 .. A 15 are set to „0“ . In the example above the starting address of the SPC3 is set to 0x1000 .

Processor

ALE

SPC3

AD 0 ..7

A8 .. 10

Addreß-

AD 0 ..7

latch

A 0..10

1,5 kByte RAM

in the SPC 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A 11.. 15

alle 0

 

 

 

 

CS

SPC3 Hardware Description

V1.3

Page 41

Copyright (C) Siemens AG 2003 All rights reserved.

 

2003/04

Page 43
Image 43