Siemens V 4.0 manual Priority, High , Medium , LOW

Models: V 4.0

1 244
Download 244 pages 54.36 Kb
Page 144
Image 144

Creating a configuration file using WinConfig

Priority...

The menu item is used to customize the PRIORITY statement in line with TAC class control.

The following dialog window is displayed when this menu item is called:

Figure 22 Dialog window: Priority-System

The following table describes the dialog window entries; the “Statement” column specifies the corresponding statement that is generated by WinConfig when saving to a configura- tion file.

Parameter name

Value

Default

Statement

 

 

 

 

High

Maximum number, the number of

0

PRIORITY

 

processes in the application that

 

 

 

can work concurrently with the TAC

 

 

 

class with the priority HIGH.

 

 

 

 

 

 

Medium

Maximum number, the number of

0

PRIORITY

 

processes in the application that

 

 

 

can work concurrently with the TAC

 

 

 

class with the priority MEDIUM.

 

 

 

 

 

 

Low

Maximum number, the number of

0

PRIORITY

 

processes in the application that

 

 

 

can work concurrently with the TAC

 

 

 

class with the priority LOW.

 

 

 

 

 

 

Sync_Wait

Specifies for which of the three TAC

-

PRIORITY

 

classes synchronous calls are per-

 

 

 

mitted. Possible values:

 

 

 

HIGH, MEDIUM, LOW

 

 

 

Selected via a pull-down menu

 

 

 

 

 

 

132

GINA V4.0 System Administrator Guide – September 2000

Page 144
Image 144
Siemens V 4.0 manual Priority, High , Medium , LOW