2.Verify the settings, as defined in Table 4.
Table 4 TCP/IP Settings
Parameter
Setting
IP Address | To assign a static IP address, enter it in this field |
| The IP address must follow the format XXX.XXX.XXX.XXX, where |
| each XXX is a number between 0 and 255. The default IP address |
| mask is 192.0.0.192. |
|
|
Subnet Mask | To assign a static subnet mask, enter it in this field |
| The subnet mask must follow the format XXX.XXX.XXX.XXX, where |
| each XXX is a number between 0 and 255. The default subnet |
| mask is 0.0.0.0. The server interprets a subnet mask of 0.0.0.0 or |
| 255.255.255.255 as no subnet mask specified. |
Default Gateway | Sets the default gateway, if your network is attached to other |
| networks |
Boot Method | Set to STATIC for a static IP address, set to DHCP or AUTO to |
| attempt to automatically assign the IP parameters from a network |
| server. |
TCP Timeout | Sets the timeout and reset values for the TCP connections |
|
|
Keepalive Timer | Blocks or broadcasts unsolicited ARP used to notify access point or |
| router that the unit is still connected. |
DNS | Sets the DNS addresses |
|
|
3.For the changes to become effective, click the Submit button, then reset the Serial Device Server.
Using AT Modem Commands
NOTE: The AT Command filter cannot be used in a FIPS
The Serial Device Server firmware has an optional data filter for configuring using AT style modem commands with the serial port. This feature allows devices with an existing AT command interface to configure the unit, if the AT commands can be properly modified. You must be familiar with the general operation of AT commands. Note that AT command processing is not enabled by default. Use the command SET PORT S1 FILTER AT to enable this feature.
All commands begin with AT and are terminated by a new line unless noted below. While standard AT commands are defined to be 40 characters or less (not including the AT), the server accepts commands of up to 80 characters.
Page 28 | Silex | Advanced Configuration |