Simer Pumps A5000-04 Table III LED Function Displays LEDs Lighted Continuously, AC power

Models: A5000-04

1 32
Download 32 pages 3.69 Kb
Page 9
Image 9

Installation

9

TABLE II – Operating Code Displays (LEDs Lighted Continuously or Flashing)

LED Operating Code Display

System Operating Condition

 

 

 

 

System Alert

 

 

 

Silenced audible alarm

 

Pump status

 

 

 

 

Charging

 

 

 

 

 

 

 

 

AC power

 

 

 

 

 

 

 

 

Battery status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicates 115V AC Power is connected

Indicates Pump is running (continuous LED)

Indicates Fast flashing LED: Pump has run

Indicates Audible alarm is switched off

Indicates Fast flashing LED: Battery pre-qualification test is running

Indicates Battery is charging normally

Indicates Continuous LED: battery charge is above 20%, system is maintaining charge

Indicates Slow flashing LED: battery charge is below 20%

= LED is ON Continuously

= LED is Flashing (Fast)

= LED is Flashing (Slow)

= LED is OFF

NOTE: All of the situations listed above indicate normal system operation; no action is required. However, if the BBU pump is running or has run, check the primary pump and actively monitor the charger status for battery life. Always reset the charger after the pump runs.

During normal system operation, the ‘System Alert’ LED does not light up. The “AC Power” LED is lighted as long as the system is plugged in to an operating AC power circuit.

TABLE III – LED Function Displays (LEDs Lighted Continuously)

Control LED:

Continuous Illumination Indicates Normal Operation:

 

 

AC Power

AC power is present.

Pump Status

The float switch has been activated. The LED remains on (flashing) after the pump

 

has stopped. Depress the‘System Test’ button to reset it.

Silenced Audible Alarm

Audible Alarm has been silenced. Press and release the ‘Silence Alarm’ button to

 

reset (activate) the audible alarm and turn OFF the LED.

Charging

Indicates that the battery is charging – see Table II, above.

Battery Status

A.

Continuous ‘ON” - the battery voltage is above 10.9 Volts DC and capacity is

 

 

above 20%.

 

B.

Slow Beep/Slow LED Flash - the battery’s capacity is below 20%, and voltage

 

 

is between 8.2VDC and 10.9VDC.

 

C.

Fast Beep/Fast LED Flash - the battery has been discharged to less than

 

 

8.2VDC.

System Alert

Flashing (in unison with the buzzer) indicates that the charger has entered ‘Failure

 

Mode’. Press the ‘System Test’ and ‘Silence Alarm’ buttons to reset it.

 

NOTE: If the source of the failure is not corrected, the charger will reenter ‘Failure

 

Mode’. See Table IV for error code information.

 

 

 

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Page 9