CHAPTER 3 INSTALLING THE SWITCH
Selecting a Site
TigerAccess 10/100 units can be mounted in a standard
•The site should:
-restrict access to authorized service personnel in accordance with IEC
-be at the center of all the devices you want to link and near a power outlet.
-be able to maintain its temperature within 0 to 50 °C (32 to 122 °F) and its humidity within 5% to 95%,
-provide adequate space (approximately five centimeters or two inches) on all sides for proper air flow
-be accessible for installing, cabling and maintaining the devices
-allow the status LEDs to be clearly visible
•Make sure
•Make sure that the unit is connected to a separate grounded power outlet within 2 m (6.6 feet) of each device and is powered from an independent circuit breaker. As with any equipment, using a filter or surge suppressor