3-1
C

HAPTER

3
I

NSTALLING

THE

S

WITCH

Selecting a Site

TigerAccess 10/100 units can be mounted in a standard 19-inch
equipment rack or on a flat surface. Be sure to follow the guidelines below
when choosing a location.
•The site should:
- restrict access to authorized service personnel in accordance with IEC
60950-1. A restricted access location is one where access is secure and
limited to service personnel who have a special key, or other means of
security.
- be at the center of all the devices you want to link and near a power
outlet.
- be able to maintain its temperature within 0 to 50 °C (32 to 122 °F) and
its humidity within 5% to 95%, non-condensing
- provide adequate space (approximately five centimeters or two inches)
on all sides for proper air flow
- be accessible for installing, cabling and maintaining the devices
- allow the status LEDs to be clearly visible
Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical interference,
such as radios and transmitters.
Make sure that the unit is connected to a separate grounded power outlet
within 2 m (6.6 feet) of each device and is powered from an independent
circuit breaker. As with any equipment, using a filter or surge suppressor