INSTALLING THE SWITCH
Wiring Map for Alarm Cable
The signals include relay contacts for major and minor system alarms, and external alarm inputs.
Table 3-2 Alarm Cable Wiring
Switch’s Alarm Port | Function | ||
|
|
| |
1 | (MJR_ALARM_CNTR) | Common contact for major alarm relay. | |
|
|
| |
2 | (MNR_ALARM_CNTR) | Common contact for minor alarm relay. | |
|
|
| |
3 | (ALARM_IN3_EXT_P*) | External alarm input 3 (external relay dry | |
|
|
| contact closure to pin 13). |
|
|
| |
4 | (ALARM_IN4_EXT_P) | External alarm input 4 (external relay dry | |
|
|
| contact closure to pin 8). |
|
|
| |
5 | (No Contact) |
| |
|
|
| |
6 | (MJR_ALARM_NO) | Normally open during major alarm state. | |
|
|
| |
7 | (MNR_ALARM_NO) | Normally open during minor alarm state. | |
|
|
| |
8 | (ALARM_IN4_EXT_RTN†) | External alarm input 4 (external relay dry | |
|
|
| contact closure from pin 3). |
|
|
| |
9 | (ALARM_IN1_EXT_P) | External alarm input 1 (external relay dry | |
|
|
| contact closure to pin14). |
|
|
| |
10 | (ALARM_IN2_EXT_P) | External alarm input 2 (external relay dry | |
|
|
| contact closure to pin 15). |
|
|
| |
11 | (MJR_ALARM_NC) | Normally closed during major alarm state. | |
|
|
| |
12 | (MNR_ALARM_NC) | Normally closed during minor alarm state. | |
|
|
| |
13 | (ALARM_IN3_EXT_RTN) | External alarm input 3 (external relay dry | |
|
|
| contact closure from pin 3). |
|
|
| |
14 | (ALARM_IN1_EXT_RTN) | External alarm input 1 (external relay dry | |
|
|
| contact closure from pin 9). |
|
|
| |
15 | (ALARM_IN2_EXT_RTN) | External alarm input 2 (external relay dry | |
|
|
| contact closure from pin 10). |
|
|
|
|
* P indicates positive input.
† RTN indicates return to Ground.