When using two or more synchronized cameras | signal. The camera will then operate synchronized to | ||||
without a camera control unit, connect an external sync | this signal. |
|
| ||
signal to the GEN LOCK IN connector on the camera | You can adjust the synchronization using the | ||||
adaptor | MAINTENANCE menus. (See page 66.) | ||||
Example 1: Camera 2 synchronized to the signal from camera 1 |
|
|
| ||
|
| BNC cable |
|
| |
| Camera 1 |
|
|
| Camera 2 |
Portable VTR |
| ||||
D50WS/D50WSP |
|
| |||
|
|
| D50WS/D50WSP | ||
|
|
|
|
| |
|
|
|
| GEN LOCK IN |
|
| VIDEO OUT |
|
|
| VIDEO OUT |
CCU/VTR/CMA | To camera | To video input |
|
| |
|
| connector | connector |
|
|
| BNC cable |
| |
Example 2: Cameras 1 and 2 synchronized to the signal from a special effects unit or similar |
| ||
|
| Camera 1 | |
|
| ||
|
| D50WS/D50WSP | |
|
|
| |
Video input connector | BNC cable | VIDEO OUT |
|
Sync signal output | BNC cable | GEN LOCK IN |
|
connector |
|
|
|
Special effects |
| Camera 2 | |
unit or similar |
| ||
|
| D50WS/D50WSP | |
|
|
| |
Video input connector | BNC cable | VIDEO OUT |
|
Sync signal output | BNC cable | GEN LOCK IN |
|
connector |
|
|
|
Connections and Fitting 2 Chapter
Chapter 2 Fitting and Connections | 37 |