Connecting a Number of Cameras (Without Using a Camera ControlUnit)

When using two or more synchronized cameras

signal. The camera will then operate synchronized to

without a camera control unit, connect an external sync

this signal.

 

 

signal to the GEN LOCK IN connector on the camera

You can adjust the synchronization using the

adaptor (CA-D50/D50P etc.), supplying a VBS or BS

MAINTENANCE menus. (See page 66.)

Example 1: Camera 2 synchronized to the signal from camera 1

 

 

 

 

 

BNC cable

 

 

 

Camera 1

 

 

 

Camera 2

CA-D50/D50P

DXC-D50/D50P/

Portable VTR

 

DXC-D50/D50P/

D50WS/D50WSP

 

 

CA-D50/D50P

 

 

 

D50WS/D50WSP

 

 

 

 

 

 

 

 

 

GEN LOCK IN

 

 

VIDEO OUT

 

 

 

VIDEO OUT

CCU/VTR/CMA

To camera

To video input

 

 

 

 

connector

connector

 

 

CCZ-A Camera Cable

 

BNC cable

 

Example 2: Cameras 1 and 2 synchronized to the signal from a special effects unit or similar

 

 

 

Camera 1

DXC-D50/D50P/

 

 

CA-D50/D50P

 

 

D50WS/D50WSP

 

 

 

Video input connector

BNC cable

VIDEO OUT

 

Sync signal output

BNC cable

GEN LOCK IN

 

connector

 

 

 

Special effects

 

Camera 2

DXC-D50/D50P/

unit or similar

 

 

 

CA-D50/D50P

D50WS/D50WSP

 

 

 

Video input connector

BNC cable

VIDEO OUT

 

Sync signal output

BNC cable

GEN LOCK IN

 

connector

 

 

 

Connections and Fitting 2 Chapter

Chapter 2 Fitting and Connections

37