Menu Operation
Submenu title | Page | Setting item: | Selectable | Remarks |
|
| Initial value | values |
|
|
|
|
|
|
<MONITOR OUT> | 10 | MONITOR OUT: ENC | ENC, Y | To select the output signal from the |
|
|
|
| MONITOR OUT connector |
|
|
|
|
|
|
| CHARACTER: ON | ON, OFF | To select if character data are to be superimposed |
|
|
|
| on the MONITOR OUT signal or not |
|
|
|
|
|
|
| RM CHARACTER: | ON, OFF | To select if character data are to be superimposed |
|
| OFF |
| on the REMOTE signal or not |
|
|
|
|
|
<TLCS> | 11 | AGC: ON | ON, OFF | To set if AGC is to be activated or not when TLCS |
|
|
|
| is activated |
|
|
|
|
|
|
| AGC LIMIT: 12 | 3, 6, 9, 12, 15, 18 | To adjust the limit value for AGC when TLCS |
|
|
|
| is activated |
|
|
|
|
|
|
| AGC CHANGE | To adjust the aperture value at which AGC (auto | |
|
| POINT: F2.8 | gain control) is to be activated when TLCS is | |
|
|
|
| activated |
|
|
|
|
|
|
| AE: ON | ON, OFF | To set if AE (electronic shutter) is to be activated or |
|
|
|
| not when TLCS is activated |
|
|
|
|
|
|
| AE LIMIT: 1/250 | 1/100, 1/150, | To set the limit value for AE (electronic shutter) |
|
|
| 1/200, 1/250 | operation when TLCS is activated |
|
|
|
|
|
|
| AE CHANGE | To set the aperture limit value at which AE | |
|
| POINT: F16 | (electronic shutter) operation is to be activated | |
|
|
|
| when TLCS is activated |
|
|
|
|
|
Menus and Indications Screen Viewfinder 4 Chapter
62 Chapter 4 Viewfinder Screen Indications and Menus