Chapter10 SetupMenus
| Menu items in the range 500 to 599, relating to tape protection | |||||||||||
|
|
|
|
|
|
|
|
| ||||
Item number | Item name | Settings | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
501 | STILL TIMER | Select the time delay from the tape transport stopping (either the “stop mode” or | ||||||||||
|
| the still playback mode in search mode) until the unit automatically switches to | ||||||||||
|
| the tape protection mode, in order to protect the video heads and the tape. | ||||||||||
|
| 0.5S to | 8M | to 30M: Set the value in the range 0.5 seconds to 30 minutes. | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
502 | TAPE PROTECTION | Select the operation of the protection mode to protect the video heads and tape | ||||||||||
| MODE FROM SEARCH | when in the still playback mode in search mode (jog/shuttle). | ||||||||||
|
| STEP | : Step forward at 1/30 normal speed every 2 seconds. | |||||||||
|
| STDBY: Switch to “Standby OFF mode” (the unit not on standby). | ||||||||||
|
| T.REL: Switch to tension release mode (the tape tension slackened). | ||||||||||
503 | TAPE PROTECTION | Select the operation of the protection mode to protect the video heads and tape | ||||||||||
| MODE FROM STOP | when stopped (the “stop mode”). | ||||||||||
|
| STDBY | : Switch to “Standby OFF mode” (the unit not on standby). | |||||||||
|
| T.REL: Switch to tension release mode (the tape tension slackened). | ||||||||||
|
| STEP: Step forward at 1/30 normal speed every 2 seconds. | ||||||||||
504 | DRUM ROTATION IN | Select whether the drum rotates in “Standby OFF mode”. | ||||||||||
| STANDBY OFF | OFF | : Drum does not rotate. | |||||||||
|
| ON: Drum rotates. | ||||||||||
|
|
|
|
|
|
|
|
| ||||
505 | STILL TENSION | Select the tape tension state in the still playback mode. | ||||||||||
|
| NORML | : Normal tape tension is maintained during still playback mode, ready for | |||||||||
|
| playback. | ||||||||||
|
| LOOSE: Reduce the tape tension further from the NORML setting. (Select | ||||||||||
|
| “LOOSE” when the unit is on standby for a long period of still playback, for | ||||||||||
|
| example, in a library management system (LMS).) | ||||||||||
|
|
|
|
|
|
|
|
| ||||
|
| Note |
|
|
|
|
| |||||
|
| When LOOSE is selected and the tape tension is reduced, playback cannot be | ||||||||||
|
| guaranteed. | ||||||||||
|
|
|
|
|
|
|
|
| ||||
| Menu items in the range 600 to 699, relating to the time code generator | |||||||||||
|
|
|
| |||||||||
Item number | Item name | Settings | ||||||||||
|
|
|
|
|
|
|
|
| ||||
601 | VITC POSITION | In 59.94i, 29.97PsF mode | ||||||||||
|
| Select a line to insert the VITC in. (For SD output) | ||||||||||
|
| 12H to | 16H | to 20H: Select any line from 12 to 20. | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Note |
|
|
|
|
| |||||
|
| You can insert the VITC signal in two places. To insert it in two places, set both | ||||||||||
|
| items 601 and 602. | ||||||||||
|
|
|
|
|
| |||||||
|
| In 50i, 25PsF mode | ||||||||||
|
| Select a line to insert the VITC in. (For SD output) | ||||||||||
|
| 9H to | 19H | to 22H: Select any line from 9 to 22. | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Note |
|
|
| |||||||
|
| You can insert the VITC signal in two places. To insert it in two places, set both | ||||||||||
|
| items 601 and 602. | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| (Continued) |