Menu items in the range 700 to 799, relating to video control

Item number

Item name

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

703

 

BLANK LINE SELECT

Switch blanking on or off for individual lines in the vertical blanking interval of the

 

 

 

 

SD video signal. The Y/C signal and odd/even fields are blanked simultaneously.

 

 

Sub-Item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

ALL LINE

 

: Specify the blanking for each line separately.

 

 

 

 

 

- - -

 

 

 

 

 

 

 

BLANK: Regardless of the setting of other sub-items, blank all lines which can be

 

 

 

 

specified in this menu item.

 

 

 

 

 

 

 

 

THROU: Regardless of the setting of other sub-items, switch off blanking for all

 

 

 

 

lines which can be specified in this menu item.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In 59.94i,

12 ...

LINE 12 ... LINE

Specify blanking for lines 12 to 20.

 

 

 

 

29.97PsF

20

20

 

 

 

 

: Carry out blanking.

 

 

 

 

BLANK

 

 

 

 

mode

 

 

THROU: Switch off blanking.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

LINE 21

Specify blanking for lines 21.

 

 

 

 

 

 

 

 

 

 

 

 

: Carry out blanking.

 

 

 

 

 

 

 

 

BLANK

 

 

 

 

 

 

 

 

HALF: Carry out half-blanking.

 

 

 

 

 

 

 

 

THROU: Switch off blanking.

 

 

 

 

In 50i, 25PsF

9 ...

LINE 9 ... LINE 22

Specify blanking for lines 9 to 22.

 

 

 

 

mode

22

 

BLANK

: Carry out blanking.

 

 

 

 

 

 

 

 

THROU: Switch off blanking.

 

 

 

 

 

 

 

 

 

 

705

 

EDGE SUBCARRIER

During recording and playback of a composite signal, in the playback circuit the

 

 

REDUCER MODE

edge subcarrier reducer (ESR) is automatically switched on or off according to

 

 

 

 

the VTR operation. When recording a “Non-Standard” signal, for example, if the

 

 

 

 

color edges are not as good as with a proper signal, the ESR can be forced on.

 

 

 

 

This item makes this selection.

 

 

 

 

 

 

 

 

AUTO

: ESR is switched on and off automatically.

 

 

 

 

 

 

 

ON: ESR operation is forced on.

 

 

 

 

707

 

FORCED VERTICAL

The “Y-add”a)function is normally switched on automatically during jog or variable

 

 

INTERPOLATION OFF

speed playback. This item selects whether or not to force the “Y-add” function

 

 

 

 

off.

 

 

 

 

 

 

 

 

 

 

AUTO

: Automatically switch the “Y-add” function on.

 

 

 

 

 

 

 

OFF: Force the “Y-add” function off.

 

 

 

 

709

 

CAV LEVEL FORMAT

Select whether the analog component output should be D-1 or Betacam.

 

 

 

 

(Selectable only in 59.94i, 29.97PsF mode)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format

Color bars

Y video

Y sync

R–Y/B–Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D-1 CAV

100/0/100/0

700 mV

300 mV

700 mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Betacam

100/7.5/77/7.5

714 mV

286 mV

700 mV

 

 

 

 

Sub-Item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

OUTPUT CAV

Select the analog component output format.

 

 

 

 

 

 

 

LEVEL

 

 

 

: Betacam

 

 

 

 

 

 

 

 

B-CAM

 

 

 

 

 

 

 

 

 

D1: D-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

710

 

INTERNAL VIDEO

Select the test signal to be output from the VTR’s internal test signal generator.

 

 

SIGNAL GENERATOR

OFF: No test signal is generated. (The VTR operates normally.)

 

 

 

 

CB

: Color bar signal

 

 

 

 

 

 

 

 

 

MLTBS: Multi-burst signal

 

 

 

 

 

 

 

 

 

10STEP: 10-step signal

 

 

 

 

 

 

 

 

 

PLSBR: Pulse and bar signal

 

 

 

 

 

 

 

 

RAMP: Ramp signal

 

 

 

 

 

 

 

 

 

BLACK: Black signal

 

 

 

 

 

 

 

 

 

To turn on the internal test signal generator, hold the F1 (VID.IN) button in

 

 

 

 

function menu HOME page for three seconds or more with this menu item set to

 

 

 

 

other than OFF. When the test signal generator is turned on, the display of the

 

 

 

 

VID.IN setting changes to SG. To turn off the test signal generator, press the F1

 

 

 

 

(VID.IN) button in function menu HOME page again.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a) The “Y-add” function is a circuit operation to interpolate

 

 

(Continued)

the video signal vertically during jog or variable speed

 

 

 

 

 

playback for the purpose of reducing the vertical

 

 

 

 

 

 

movement of the playback picture.

 

 

 

 

 

 

 

 

 

 

 

Chapter10 SetupMenus

Chapter 10 Setup Menus 10-23