10-4 Items in the Extended Setup Menu

Menu items in the range 600 to 699, relating to the time code generator (Continued)

Item number

Item name

Settings

 

 

 

 

 

 

608

PHASE CORRECTION

Select whether or not to carry out phase correction control on the LTC generated

 

 

by the time code generator.

 

 

OFF

: No control

 

 

ON:

Carry out control.

609

TCG CF FLAG

Select whether or not the color framing flag is set in the blank bit of the time code

 

 

data.

 

 

OFF

: Color framing flag is not set.

 

 

ON: Color framing flag is set.

 

 

AUTO: Color framing flag is set or not depending upon the color framing phase

 

 

relationship between the recorded video signal and the time code signal.

 

 

When AUTO is selected, color framing is controlled as follows according to the

 

 

operating mode of the time code generator.

 

 

• In INT PRESET mode (F1 (TCG) is set to INT and F2 (PR/RGN) set to PRESET

 

 

in function menu page 1, and in modes other than the automatic editing mode):

 

 

the time code signal is generated with color framing locked to the video signal,

 

 

and the color framing flag is set.

 

 

• In INT REGEN mode (F1 (TCG) is set to INT and F2 (PR/RGN) set to LTC or

 

 

VITC in function menu page 1, and in the automatic editing mode), and also in

 

 

EXT mode (F2 (PR/RGN) is set to EXT): the time code signal is generated

 

 

without color framing locked to the video signal, and the color framing flag is not

 

 

set.

 

 

 

 

 

610

REGEN CONTROL

Select whether or not the time code is automatically regenerated.

 

MODE

 

 

: In automatic editing carried out in either assemble mode or insert mode

 

AS&IN

 

 

with this unit as the recorder, regardless of the settings of F1 (TCG) and F2

 

 

(PR/RGN) in function menu page 1, the time code generator regenerates

 

 

according to the time code on the tape.

 

 

ASSEM: In automatic editing carried out in assemble mode with this unit as the

 

 

recorder, regardless of the settings of F1 (TCG) and F2 (PR/RGN) in function

 

 

menu page 1, the time code generator regenerates according to the time code

 

 

on the tape.

 

 

MANU: Regardless of whether this unit is the recorder or player, the time code

 

 

generator operates in accordance with the settings of F1 (TCG) and F2 (PR/

 

 

RGN) in function menu page 1.

 

 

FULL: Whether local or remote and regardless of the settings of F1 (TCG) and

 

 

F2 (PR/RGN) in function menu page 1, when any of the ASSEMBLE, VIDEO,

 

 

CH1 to CH4, CUE and TC buttons is lit, the time code generator regenerates

 

 

according to the time code played back from the tape.

617

LTC OUTPUT PHASE

Set the output phase of time code signals (LTC).

 

SELECT

TCG/R

: Output the playback time code signal during playback.

 

 

When the edit preset function is on, and when recording, output the time code

 

 

signal generated by the internal time code generator.

 

 

INPUT: Use the same phase as the input video.

 

 

OUTPUT: Use the same phase as the output video.

 

 

AUTO: Use the same phase as the input video when editing, and use the same

 

 

phase as the output video at other times (playback, recording, etc.)

 

 

 

 

618

UPCONV EMBEDDED

Select the source time code for HD-SDI embedded VITC which is output after

 

VITC (HDW-M2000 only)

subjected to up-conversion during playback of SD-format tape.

 

 

when

 

 

 

: Select VITC recorded on SD-format tape.

 

 

VITC

 

 

LTC : Select LTC recorded on SD-format tape.

 

 

 

 

 

 

10-20Chapter 10 Setup Menus