Menu items in the range 600 to 699, relating to the time code generator (Continued)
Item number | Item name | Settings | |||
|
|
|
|
|
|
608 | PHASE CORRECTION | Select whether or not to carry out phase correction control on the LTC generated | |||
|
| by the time code generator. | |||
|
| OFF | : No control | ||
|
| ON: | Carry out control. | ||
609 | TCG CF FLAG | Select whether or not the color framing flag is set in the blank bit of the time code | |||
|
| data. | |||
|
| OFF | : Color framing flag is not set. | ||
|
| ON: Color framing flag is set. | |||
|
| AUTO: Color framing flag is set or not depending upon the color framing phase | |||
|
| relationship between the recorded video signal and the time code signal. | |||
|
| When AUTO is selected, color framing is controlled as follows according to the | |||
|
| operating mode of the time code generator. | |||
|
| • In INT PRESET mode (F1 (TCG) is set to INT and F2 (PR/RGN) set to PRESET | |||
|
| in function menu page 1, and in modes other than the automatic editing mode): | |||
|
| the time code signal is generated with color framing locked to the video signal, | |||
|
| and the color framing flag is set. | |||
|
| • In INT REGEN mode (F1 (TCG) is set to INT and F2 (PR/RGN) set to LTC or | |||
|
| VITC in function menu page 1, and in the automatic editing mode), and also in | |||
|
| EXT mode (F2 (PR/RGN) is set to EXT): the time code signal is generated | |||
|
| without color framing locked to the video signal, and the color framing flag is not | |||
|
| set. | |||
|
|
|
|
| |
610 | REGEN CONTROL | Select whether or not the time code is automatically regenerated. | |||
| MODE |
|
| : In automatic editing carried out in either assemble mode or insert mode | |
| AS&IN | ||||
|
| with this unit as the recorder, regardless of the settings of F1 (TCG) and F2 | |||
|
| (PR/RGN) in function menu page 1, the time code generator regenerates | |||
|
| according to the time code on the tape. | |||
|
| ASSEM: In automatic editing carried out in assemble mode with this unit as the | |||
|
| recorder, regardless of the settings of F1 (TCG) and F2 (PR/RGN) in function | |||
|
| menu page 1, the time code generator regenerates according to the time code | |||
|
| on the tape. | |||
|
| MANU: Regardless of whether this unit is the recorder or player, the time code | |||
|
| generator operates in accordance with the settings of F1 (TCG) and F2 (PR/ | |||
|
| RGN) in function menu page 1. | |||
|
| FULL: Whether local or remote and regardless of the settings of F1 (TCG) and | |||
|
| F2 (PR/RGN) in function menu page 1, when any of the ASSEMBLE, VIDEO, | |||
|
| CH1 to CH4, CUE and TC buttons is lit, the time code generator regenerates | |||
|
| according to the time code played back from the tape. | |||
617 | LTC OUTPUT PHASE | Set the output phase of time code signals (LTC). | |||
| SELECT | TCG/R | : Output the playback time code signal during playback. | ||
|
| When the edit preset function is on, and when recording, output the time code | |||
|
| signal generated by the internal time code generator. | |||
|
| INPUT: Use the same phase as the input video. | |||
|
| OUTPUT: Use the same phase as the output video. | |||
|
| AUTO: Use the same phase as the input video when editing, and use the same | |||
|
| phase as the output video at other times (playback, recording, etc.) | |||
|
|
|
| ||
618 | UPCONV EMBEDDED | Select the source time code for | |||
| VITC | subjected to | |||
|
| when | |||
|
|
| : Select VITC recorded on | ||
|
| VITC | |||
|
| LTC : Select LTC recorded on | |||
|
|
|
|
|
|