| Items 400 to 499: Settings for preroll | |
|
|
|
|
|
Item | Item name |
| Settings | |
number |
|
|
|
|
401 | FUNCTION MODE AFTER |
| Select the state that the unit goes into after a | |
| CUEUP |
| [STOP]: Stop (the stop mode) | |
|
|
| STILL: Still playback (in search mode) | |
|
|
|
| |
|
|
| Note |
|
|
|
| When | controlling this unit from an editor with the standard constants set, select STOP. |
|
|
|
| |
402 | TIME REFERENCE FOR |
| When prerolling a tape with timecode discontinuity, select whether or not to use CTL | |
| PREROLL |
| pulses to count timecode from before a discontinuity. | |
|
|
| [CTL]: Use CTL pulses to count timecode. | |
|
|
| TC: Do not use CTL pulses to count timecode. | |
|
|
|
| |
403 | AUTOMATIC PREROLL |
| Select whether or not the IN point is automatically set by pressing the PREROLL button, | |
| REFERENCE ENTRY |
| when the IN point is not set before starting preroll. | |
|
|
| [DIS]: IN point is not set automatically. | |
|
|
| ENA: IN point is set automatically. | |
|
|
|
| |
405 | CUEUP BY CTL |
| Select the tape transport mode when cuing. This setting is valid only when CTL/TC on | |
|
|
| the HOME page of the function menu is set to CTL. | |
|
|
| [CAP]: During cuing up, the tape transport is in the pinch ON state (maximum tape | |
|
|
| speed 10 times normal). | |
|
|
| REEL: During cuing up, the tape transport is in the pinch OFF state. As the tape | |
|
|
| approaches the cue up point and the tape speed drops, the tape transport switches | |
|
|
| to the pinch ON state.a) | |
|
|
| To give priority to editing accuracy, select CAP. | |
|
|
|
|
|
a)When controlling with an editor such as a
|
| Items 500 to 599: Settings for tape protection |
|
|
|
Item | Item name | Settings |
number |
|
|
501 | STILL TIMER | Select the time delay from the tape transport stopping (either the stop mode or the still |
|
| playback mode in search mode) until the unit automatically switches to the tape |
|
| protection mode, in order to protect the video heads and the tape. |
|
| 0.5S to [8M] to 30M: Set the value in the range 0.5 seconds to 30 minutes. |
|
|
|
502 | TAPE PROTECTION | Select the operation of the protection mode to protect the video heads and tape when in |
| MODE FROM SEARCH | the still playback mode in search mode (jog/shuttle). |
|
| [STEP]: Step forward at 0.2 time of the normal speed for 0.2 second. |
|
| STDBY: Switch to Standby OFF mode (the unit not on standby). |
|
| T.REL: Switch to tension release mode (the tape tension slackened). |
|
|
|
503 | TAPE PROTECTION | Select the operation of the protection mode to protect the video heads and tape when |
| MODE FROM STOP | stopped (the stop mode). |
|
| [STDBY]: Switch to Standby OFF mode (the unit not on standby). |
|
| T.REL: Switch to tension release mode (the tape tension slackened). |
|
| STEP: Step forward at 0.2 time of the normal speed for 0.2 second. |
|
|
|
Menus Setup 9 Chapter