Sony KP-61SV70C Electrical Adjustment by Remote Commander, Adjust Buttons and Indicator

Models: KP-43T70C KP-53SV70C KP-61SV70C

1 92
Download 92 pages 49.95 Kb
Page 30
Image 30

KP-43T70C/53SV70C/61SV70C

RM-Y906 RM-Y906 RM-Y906

3-9. ELECTRICAL ADJUSTMENT BY REMOTE

COMMANDER

By using Remote Commander (RM-Y906),all circuit adjustments

can be made.

NOTE : Test Equipment Required.

1.Pattern Generator

2.Frequency counter

3.Digital multimeter

4.Audio oscillator

1. METHOD OF SETTINGTHE SERVICE ADJUSTMENT MODE

SERVICE MODE PROCEDURE 1. Standby mode. (Power off)

2. MEMORY WRITE CONFIRMATION METHOD

1.After adjustment, remove the plug from AC outlet, and then replace the plug in AC outlet again.

2.Turn the power switch ON and set to Service Mode.

3.Call the adjusted items again and confirm they were adjusted.

3. ADJUST BUTTONS AND INDICATOR

MUTING

MUTING

DVD/

SAT/

POWER

TV POWER ON

 

VTR

CABLE

 

 

 

 

 

TV

 

 

SYSTEM

 

FUNCTION

 

 

 

OFF

DVD/VTR SAT/CABLE

TV

 

2. DISPLAY n 5 n VOL (+) n TV POWER

on the Remote Commander.

(Press each button within a second.)

SERVICE MODE ADJUSTMENT

Category Adjustment item

DATA

SERVICE VPNT VPOS 031 000000 00

TV/VTR

FREEZE

SWAP

PIP

 

m

N

M

 

POSITION

AUDIO

ACTIVE

X

z

x

 

Category up

SLEEP

ANT

TV/VIDEO

PICTURE

CC

MTS/SAP

DISPLAY

MODE

 

1

2

3

Adjustment

4

5

6

item up

 

 

 

 

7

8

9

 

JUMP

0

ENTER

Adjustment

 

 

 

 

 

item down

INDEX

GUIDE

DISPLAY

Data up

Data down

Category down

ENTER

(SCREEN DISPLAY)

3.The SCREEN displays the item being adjusted.

4.Press 1 or 4 on the Remote Commander to select the adjustment item.

5.Press 3 or 6 on the Remote Commander to change the data.

6.Press 2 or 5 on the Remote Commander to select the category.

7.If you want to recover the latest values press - then [ENTER] to read the memory.

8.Press [MUTING] then [ENTER] to write into memory.

9.Turn power off.

Note: Press 8 then [ENTER] on the Remote Commander to initialize or turn set off and on to exit.

RESETMENU

RM-Y906

Note : In the PJE mode these are different a little. See page 43.

– 30 –

Page 30
Image 30
Sony KP-61SV70C Electrical Adjustment by Remote Commander, Adjust Buttons and Indicator, Memory Write Confirmation Method