Sony LX40, LX70S Mechanical Adjustments, Electrical Adjustments, Preparation Before Adjustment

Models: LX50 RMT-V294A LX40 LX60S RMT-V293A LX70S

1 71
Download 71 pages 3.4 Kb
Page 52
Image 52

SLV-LX40/LX50/LX60S/LX70S

SECTION 6

ADJUSTMENTS

6-1 MECHANICAL ADJUSTMENTS

For the mechanical adjustments, please refer to the

“VHS MECHANICAL ADJUSTMENT MANUAL (S MECHANISM)” (9-921-647-11).

6-2. ELECTRICAL ADJUSTMENTS

2-1-3. Set-up of Adjustment

In this adjustment, NTSC pattern generator is connected with LINE input terminal. When check to tuner, connected AERIAL terminal. Check that the synchronizing signal of the Y signal has an amplitude of approximately 0.7 V and that the burst signal has an amplitude of approximately 0.3 V and its waveform is flat. And check that the level ratio of burst signal to “red” signal is 0.30 : 0.66. The video signal (color bar) used for electrical aligning this unit is shown in Fig. 6-2-2.

See the adjusting part location diagram from on page 6-6 for the adjustment.

2-1. PREPARATION BEFORE ADJUSTMENT

2-1-1. Equipment Required

The measuring instruments used for this alignment include:

1)

Monitor TV

2)

Oscilloscope, dual-trace, bandwidth of 30 MHz or more, with

 

delay mode (A probe 10:1 should be used unless otherwise

 

specified.)

3)

Frequency counter

NTSC model

About 0.7 V

About 0.3 V

White (100%)

Red

About 0.3 V

Burst signal

4)

NTSC Pattern generator

5)

Remote commander

6)

Digital voltmeter

Horizontal sync signal

(It must be flat.)

7)

Audio generator

8)

Audio level meter

9)

Audio attenuator

10)

Alignment tapes

 

KRV-51N2 (NTSC) Part No. : 8-192-605-32

2-1-2. Equipment Connection

Unless otherwise specified, connect and adjust the measuring instruments as shown in the following diagram.

VIDEO LINE IN

 

Pattern generator

VCR

Monitor TV

Video output

VIDEO LINE OUT

(75Ω)

 

 

 

Fig. 6-2-1

 

Fig. 6-2-2 Color Bar Signals of Pattern Generator

2-1-4. Alignment Tape

Contents of KRV-51N2

 

Mode

Period

Video signal

Audio signal

 

 

 

 

Hi-Fi

Normal

 

 

 

 

 

 

 

 

 

 

1

SP

7 minutes

Color bar

 

 

 

 

 

400Hz

 

2

3 minutes

Monoscope

400Hz

 

 

 

 

 

(L/R)

3

LP

7 minutes

Color bar

 

 

 

 

 

 

4

3 minutes

Monoscope

 

 

 

 

 

6-1

Page 52
Image 52
Sony LX40, LX70S, RMT-V293A, RMT-V294A, LX60S Mechanical Adjustments, Electrical Adjustments, Preparation Before Adjustment