RS-232C Protocol
The connection of
Format |
| Serial |
|
Electrical characteristics |
| ||
|
| ||
|
| compatible with the | |
|
| ||
|
| professional use) | |
Connector | |||
Pin assignment and I/O signals | |||
Pin No. | I/O | Signal | Description |
|
|
|
|
1 | — | N. C. | Not used. |
|
|
|
|
2 | I | RxDATA | Inputs reception data. |
|
|
|
|
3 | O | TxDATA | Outputs transmission data. |
|
|
|
|
4 | O | DTR | Notifies that the set is ready |
|
|
| for communication. |
|
|
|
|
5 | — | GND | Ground |
|
|
|
|
6 | I | DSR | Acknowledges that the |
|
|
| personal computer is ready |
|
|
| for communication. |
|
|
|
|
7 | O | RTS | Notifies that the set |
|
|
| requests data transmission. |
|
|
|
|
8 | I | CTS | Acknowledges that the |
|
|
| personal computer requests |
|
|
| data transmission. |
|
|
|
|
9 | — | N. C. | Not used. |
|
|
|
|
Synchronous mode between MDS-B5 and the personal computer
Adjust the transmission rate, bit length, parity and stop bit length. The following provides a setting method.
Contents of menu set screen
Items | Contents |
Transmission rate | 1200, 2400, 4800, 9600 (bauds) |
|
|
Parity | OFF, ODD, or EVEN |
|
|
Stop bit length | Stop bit1 or Stop bit 2 |
|
|
1Press the EDIT/NO button on the deck while holding down the STOP button.
The Setup menu appears in the display window.
2Turn the AMS control to display the menu item you want to set (F13: baud rate, F14: parity bit, or F15: stop bit).
3Press the AMS control.
4Turn the AMS control to select the setting value.
5Press the AMS control again to affect the selection. The settings are saved even after the power is turned off and on again.
Communication with the RS-232C interface terminal on the personal computer side
When connecting the
Connect the DSR of
Also, connect the CTS of the
Appendix
Appendix