6-71-Overview2 LevelSyncof EditingSettingFunctions(Track Marking Function)

Menu Setup 7 Chapter

LevelSync function adds track numbers automatically at specified points where the rise in the audio signal is detected during recording.

You can set the following items as well as turning on and off of LevelSync function using the setup menu for fitting your needs.

Turning on and off of the LevelSync function (F06: Levelsync)

The factory setting is off.

Threshold level for the LevelSync function (F16: Levelsync threshold)

You can adjust the threshold level for detecting as a silence portion of audio signal. –50 dB (factory setting) is the threshold level used to detect the rise in audio signal from a silence portion. You can adjust this level according to the input signal ranging from –72 dB to 0 dB.

The minimum length of the silence portion to be detected (F17: Levelsync width)

You can set the minimum length of the silence portion to be detected. If the silence portion lasts longer than

1.5second, this portion is regarded as a track, and the track number will be marked when the following rise in the audio signal comes. You can adjust the minimum length to detect ranging from 0.0 second to

9.5seconds with reference to the input signals.

LevelSync offset function (F18: Levelsync offset)

The LevelSync offset function allows you to adjust the margin between the position where the track number is marked and the rise in the audio signal. You can tune finely the starting point of playback using this function.

You can shift up to 9 seconds 85 frames before or after the rise in the audio signal regarded as 0 second 0 frame (factory setting). However, you cannot mark the track number at the position before the silence portion starts.

 

 

Silence portion

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum length of the

 

Margin between the

silence portion to be

 

 

 

 

 

track number position

detected

 

 

 

 

 

and the rise in the

Track number is

 

 

audio signal

 

 

 

 

 

 

 

marked here.

To set the items for the LevelSync function

 

= +

 

0 )

p (P

r

1

2 – 5

1 Press the EDIT/NO button while holding down the STOP button.

The Setup menu appears.

2 Turn the AMS control until the item you want to set is displayed.

F06: Levelsync

F16: Levelsync threshold

F17: Levelsync width

F18: Levelsync offset

3 Press the AMS control.

The indication flashes to show that you can change the setting.

4 Turn the AMS control to select the setting values.

5 Press the AMS control to affect the selection and exit from the Setup menu.

7-2Chapter 7 Setup Menu