6-71-Overview10 Disablingof EditingtheFunctionsButtons While Controlling Remotely

When you control the MDS-B5 with the remote controller or the keyboard or use the deck as a sub or end deck during direct ATRAC data copying, you can disable the buttons on the front panel of the MDS-B5 to avoid unintentional touch of the operation buttons (Kill Local function). You can choose from two setting modes (“Kill Almost” and “Kill All”).

For the connection when you use the direct ATRAC data copy function, see “3-2-3 Connection for Direct ATRAC Data Copying” on page 3-3.

4 Turn the AMS control to select the mode from the values below.

Kill Almost: Only the STOP, EJECT, and DISPLAY buttons are in effect.

Kill All: All the buttons on the front panel are disabled.

5 Press the AMS control to affect the setting and exit from the Setup menu.

Disabling the buttons on the front panel

Menu Setup 7 Chapter

 

= +

 

0 )

p (P

r

1

2 – 5

1 Press the EDIT/NO button while holding down the STOP button.

The Setup menu appears.

2 Turn the AMS control until the menu item F26 (“Kill Almost” or “Kill All”) appears.

F26

K i l l A l m o s t

3 Press the AMS control.

The indication flashes to show that you can change the setting.

7-10Chapter 7 Setup Menu