Sony MDS-NT1 ENTER/YES to save it, Iop NV SAVE, Traverse Adjustment, Specified Value, Procedure

Models: MDS-NT1

1 70
Download 70 pages 10.41 Kb
Page 32
Image 32
[ENTER/YES] to save it.
+
oscilloscope (DC range)

MDS-NT1

6.Click the [JOG UP] or [JOG DOWN] so that the reading of the laser power meter becomes specified value, click the

[ENTER/YES] to save it.

Specified Value:

Laser power meter reading: 8.2 to 8.6 mW (KMS-262A) 8.5 to 8.8 mW (KMS-262E)

Note: Do not perform the emission with 8.4 mW more than 15 seconds continuously.

7.Then, click the [JOG UP] or [JOG DOWN] to display “LDPWR CHECK” (C13).

8.Click the [ENTER/YES] once to display “L 0.90 mW $ 5-12. Iop NV SAVE5-13. TRAVERSE ADJUSTMENT ”. Check that the reading of the laser power meter become speci- fied value.

Specified Value:

Laser power meter reading: 0.84 to 0.92 mW (KMS-262A)

0.90to 0.96 mW (KMS-262E)

9.Click the [ENTER/YES] button once more to display “L 8.40 mW $ Manual backgroundManual background(KMS-262A) or “L 8.65 mW $ Manual backgroundManual background(KMS-262E). Check that the reading the laser power meter and digital volt- meter satisfy the specified value.

Note down the digital voltmeter reading value.

Specified Value:

Laser power meter reading : 8.4 ± 0.3 mW (KMS-262A) 8.65 ± 0.25 mW (KMS-262E)

Digital voltmeter reading : Value on the optical pick-up label

±10%

(Optical pick-up label)

KMS262A

(For details of the method for

20101

checking this value, refer to “8.

Recording and Displaying the Iop

B0825

Information”.)

 

 

Iop = 82.5 mA in this case

Iop (mA) = Digital voltmeter reading (mV)/1 ()

10.Click the [MENU/NO] to display “LDPWR CHECK” (C13) and stop the laser emission.

(The [MENU/NO] is effective at all times to stop the laser emission.)

11.Click the [JOG UP] or [JOG DOWN] to display “Iop Write” (C05).

12.Click the [ENTER/YES]. When the display becomes Ref=@@@.@ (@ is an arbitrary number), click the [ENTER/YES] to display “Measu=@@@.@” (@ is an arbitrary number).

13.The numbers which can be changed will blink. Input the Iop value noted down at step 9.

To select the number : Click the [JOG UP] or [JOG DOWN].

To select the digit : Click the [PUSH].

14.When the [ENTER/YES] is clicked, “Complete!” will be dis- played momentarily. The value will be recorded in the non- volatile memory and the display will become “Iop Write” (C05).

Note: After step 4, each time the [ENTER/YES] is clicked, the display

will be switched “L 0.70 mW $ Manual backgroundManual backgroundManual backgroundManual background ” and “LD 7.50 mW $ Manual backgroundManual background ”. Nothing needs to be performed here.

Adjustment Location: BD board (see page 35)

5-12. Iop NV SAVE

Write the reference values in the nonvolatile memory to perform “Iop compare”. As this involves rewriting the reference values, do not perform this procedure except when adjusting the laser power during replacement of the optical pick-up and when replacing the IC102. Otherwise the optical pick-up check may deteriorate.

Note: Perform this function with the optical pick-up set at room tempera- ture.

Procedure:

1.Click the [JOG UP] or [JOG DOWN] to display “Iop NV Save” (C06).

2.Click the [ENTER/YES] and display “Iop [stop]”.

3.After the display changes to “Iop =xxsave?”, click the [ENTER/YES].

4.After “Complete!” is displayed momentarily, the display changes to “Iop 8.4 mW”.

5.After the display changes to “Iop=yysave?”, click the [ENTER/YES].

6.When “Complete!” is displayed, it means that Iop NV saving has been completed.

5-13. TRAVERSE ADJUSTMENT

Note 1: Data will be erased during MO reading if a recorded disc is used in this adjustment.

Note 2: If the traverse waveform is not clear, connect the oscilloscope as shown in the following figure so that it can be seen more clearly.

BD board

Manual background 330 k

CN105 pin 4 (TE)

CN105 pin 6 (VC) Manual backgroundManual background 10 pF

Connection:

oscilloscope (DC range)

BD board

 

 

CN105 pin 4

(TE)

+

V: 0.1 V/div

CN105 pin 6

(VC)

H: 10 ms/div

 

 

 

Adjusting Procedure:

1.Connect an oscilloscope to CN105 pin 4 (TE) and CN105 pin 6 (VC) on the BD board.

2.Load a disc (any available on the market). (Refer to Note 1)

3.Click the [STOP] after the [FF] clicked to move the optical pick-up outside the pit.

4.Click the [JOG UP] or [JOG DOWN] to display “EF MO ADJUST” (C07).

5.Click the [ENTER/YES] to display “EFB = Manual backgroundManual background MO-R”. (Laser power READ power/Focus servo ON/tracking servo OFF/spindle (S) servo ON)

6.Click the [JOG UP] or [JOG DOWN] so that the waveform of the oscilloscope becomes the specified value.

(When the [JOG UP] or [JOG DOWN] is clicked, the Manual backgroundManual background of “EFB= Manual backgroundManual background” changes and the waveform changes.) In this ad- justment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible.

(Read power traverse adjustment)

Traverse Waveform

A

VC

B

Specification A = B

32

Page 32
Image 32
Sony MDS-NT1 service manual ENTER/YES to save it, Iop NV SAVE, Traverse Adjustment, Specified Value, Procedure, Connection