65.Adjust with the [VOL+] key (adjusted value up) or [VOL--]key (adjusted value down) so that the adjusted value becomes 1C.

Remote commander LCD display

0230D751C

1C:Adjusted value

66.Press the X key.

(0D75 is blinking)

67.Press the [VOL+] key once to change the blinking portion to 0D76.

Remote commander LCD display

0230D7600

00:Adjusted value

68.Press the x key.

(00 is blinking)

69.Adjust with the [VOL+] key (adjusted value up) or [VOL--]key (adjusted value down) so that the adjusted value becomes 03.

Remote commander LCD display

0230D7603

03:Adjusted value

70.Press the X key.

(0D76 is blinking)

71.Press the [VOL+] key to change the blinking portion to 0D78.

Remote commander LCD display

0230D7800

00:Adjusted value

72.Press the x key.

(00 is blinking)

73.Adjust with the [VOL+] key (adjusted value up) or [VOL--]key (adjusted value down) so that the adjusted value becomes 01.

Remote commander LCD display

0230D7801

01:Adjusted value

74.Press the X key.

(0D78 is blinking)

75.Press the [VOL+] key once to change the blinking portion to 0D79.

Remote commander LCD display

0230D7900

00:Adjusted value

76.Press the x key.

(00 is blinking)

77.Adjust with the [VOL+] key (adjusted value up) or [VOL--]key (adjusted value down) so that the adjusted value becomes E0.

Remote commander LCD display

0230D79E0

E0:Adjusted value

78.Press the X key. (0D79 is blinking)

79.Press the [DISPLAY] key on the remote commander for sev- eral seconds (about 3 seconds) to exit the patch data write mode (to return to the manual mode display in the test mode).

Remote commander LCD display

023 Patch 01

01:Adjusted value

80.Press the X key to write the modified data. (The adjusted value changes to CC)

81.The modified data writing is over, if the adjusted value changes to DD.

Remote commander LCD display

023***SDD

DD:Adjusted value

82. Turn the power off.

• Modified Data Writing Method (version 1.200 and later)

1.Select the manual mode of the test mode, and set item number 022 (see page 13).

Remote commander LCD display

022 PatClr CC

2.Press the X key to initialize the patch data.

(The modified data writing is over, if the adjusted value changes to DD)

Remote commander LCD display

022***SDD

DD:Adjusted value

3. Turn the power off.

26

Page 26
Image 26
Sony MZ-R900 service manual 023 0D751C, 023 0D7600, 023 0D7603, 023 0D7800, 023 0D7801, 023 0D7900, 023 0D79E0, Patch