Message list after Auto Calibration measurement

DisplayExplanation

E - xxx* : 31 SPEAKERS (OFF/A/B/A+B) is set to OFF. Set it to others and perform the measurement again.

E - xxx* : 32 None of the speakers were detected. Make sure that the optimizer microphone is connected properly and perform the measurement again. If the optimizer microphone is connected properly but the error code appears, the optimizer microphone cable may be damaged or improperly connected.

E - xxx* : 33 • None of the front speakers are connected or only one front speaker is connected.

The optimizer microphone is not connected.

Either the left or right surround speakers is not connected.

Surround back speakers are connected even though surround speakers are not connected. Connect the surround speaker(s) to the SURROUND terminals.

The surround back speaker is connected only to the SPEAKERS SURROUND BACK R terminals. When you connect only one surround back speaker, connect it to the SPEAKERS SURROUND BACK L terminals.

W - xxx* : 40 The measurement has completed. However, the noise level is high. You may be able to perform the measurement properly if you try it again, even though the measurement cannot be performed in all environments. Try to perform the measurement in a quiet environment.

W - xxx* : 41 The sound input from the optimizer microphone is outside the acceptable range. It is louder than the loudest sound that can be measured. Try to perform the measurement when the environment is quiet enough to allow proper measurement.

W - xxx* : 42 The volume of the receiver is out of the acceptable range. Try to perform the measurement when the environment is quiet enough to allow proper measurement.

W - xxx* : 43 The distance and position of a subwoofer cannot be detected. This may be caused by

noise. Try to perform the measurement in a quiet environment.

NO WARNING

There is no warning information.

 

 

* xxx represent a speaker channel (F, FL, FR, CNT, S, SL, SR, SB, SBL, SBR, SW).

Started Getting

continued

35GB