Disposal the used lamp

The used lamp contains Mercury, dispose according to local, state or federal laws.

As the materials used in this lamp are similar to those of a fluorescent lamp, you should dispose of a used projector lamp in the same way as a fluorescent lamp.

Replacing the Air Filter

The air filter should be replaced periodically. When “Please replace the filter.” appears on the screen, replace the air filter immediately.

Notes

Replacing the air filter is very important to maintain the high efficiency of the projector and to prevent a malfunction. When the replacement message appears on the screen, replace the air filter without delay. It is recommended to replace the air filter approximately every 1000 hours of use.

When removing the air filter from the projector, be careful that no dust or object gets into the inside of the projector.

1Place a protective sheet (cloth) beneath the projector. Turn the projector over so you can see its underside.

Note

Be sure that the projector is stable after turning it over.

2Open the filter cover while pushing the filter lock knobs inward.

3Remove the air filter from the projector by holding the tab on the filter cover.

4Insert the new air filter into the projector.5Replace the filter cover.

Others

Replacing the Air Filter 63 GB