■Transferring the LUT Binary
[Command] | lut transfer |
[Process] | Transfers the binary file of 1024 bytes |
| using the Kermit protocol. |
<Example> | lut transfer<CR> |
| |
| University, |
| Escape back to your local Kermit and |
| give a SEND command. |
| KERMIT READY TO |
| RECEIVE...<CR> |
Note
To stop the transfer, press Ctrl + C.
■Current GAMMA Setting
[Command] | lut |
[Process] | Displays the gamma value of the |
|
■Help of the GAMMA Setting [Command] lut
[Process] Displays the help of the GAMMA Setting command.
■LUT Inquiry
[Command] | lut query |
[Process] | Dumps the LUT setting presently set |
| to the computer. |
Camera Gain Control Setting
■GAIN Setting [Command] gain GAIN
[Parameter] GAIN: 0 to 18 [dB] (1 step)
[Process] | Sets the gain. |
<Example> | Setting the gain to 18 dB |
| gain 18<CR> |
| camera gain complete<CR> |
■Current GAIN Setting
[Command] | gain |
[Process] | Displays the current gain value. |
■Help of the GAIN Setting
[Command] | gain |
[Process] | Displays the help of the GAIN Setting |
| command. |
External Control Commands
Camera BINNING Settings
■BINNING Settings [Command] binning VALUE [Parameter] VALUE: 0 to 3
0:Horizontal = OFF, Vertical = OFF
1:Horizontal = OFF, Vertical = ON
2:Horizontal = ON, Vertical = OFF
3:Horizontal = ON, Vertical = ON
[Process] | Sets the binning. |
<Example> | Setting both the Horizontal and |
| Vertical to OFF |
| binning 0<CR> |
| camera binning complete<CR> |
■Current BINNING Setting [Command] binning
[Process] | Displays the current binning setting. |
■Help of the BINNING Setting [Command] binning
[Process] Displays the help of the BINNING Setting command.
Camera Partial Scan Settings
■Partial Scan Settings
[Command]
[Parameter] HORIZONTAL: off, on
| when Veritical is set to on.) |
| |
| is set to on.) |
[Process] | Sets the partial scan. |
<Example> | Setting the partial scan. |
| partial |
| camera partial complete<CR> |
Note
When setting the Partial Scan Setting to ON, input both the
■Current Partial Scan Setting
[Command] | partial |
[Process] | Displays the current partial scan |
| setting. |