HEAVY DUTY COUNTERLINE

INSTALLATION

Step 2e: Installation on Floor Stand (60" and 72" Models)

A 60" or 72" griddle may be installed on top of an optional floor stand (for 24", 36", and 48" griddles, go to Step 2d on page 13). The floor stand is shipped in a separate crate and must be assembled, as follows:

1.Position the bottom-brace pieces on a flat surface, as shown in Figure 10 below. There are four bottom-side braces (items “A”), and four front/rear bottom-braces (items “B”).

2.Position a corner brace (item “C”) in each interior corner, matching the pre-punched holes on the lower inside flange of the bottom braces.

3.Position the six leg brackets (item “D”); one in each corner of the stand, one front-center, and one rear- center, as shown in Figure 10. Be sure that the bracket flanges are engaged into the open hem of the bottom braces.

4.Use the thirty-two 1/2"-long hex head bolts (items “E”), lock washers (items “F”), and acorn nuts (items “G”) to bolt the corner braces to the bottom braces. Only hand-tighten for now.

5.Check that the leg brackets are in the proper position, and that the outside corners are square.

Figure 10

 

 

 

 

 

A

 

E

 

 

 

 

 

 

 

 

 

 

B

 

 

 

C

 

 

 

 

 

 

 

C

 

 

 

D

C

D

 

 

E

A

 

 

 

 

 

 

B

 

 

 

 

 

F

 

 

 

 

 

G

 

A

C

 

 

 

 

 

 

B

 

 

 

C

 

 

 

 

 

 

 

D

C

D

 

 

 

A

 

 

 

 

 

 

 

B

 

 

 

6.Use the twelve 1-1/2" hex bolts (items “H” in Figure 11) to attach the two left-legs (items “I”), the two right-legs (items “J”), and the two center-legs (items “P”). “Left” and “right” are as seen from the front or rear of the stand. Be sure that the small threaded-insert near the top of each leg faces either the front or the rear of the stand, not a side. Insert the bolts through the leg brackets and into the legs. Only hand-tighten the bolts for now.

OWNERS MANUAL 1182845 REV 8

PAGE 15

INSTALLATION

Page 15
Image 15
Southbend HDG-36-M, HDG-60-M, HDG-72-RE, HDG-36-RE, G-72-M, HDG-48-M, HDG-24-M Installation on Floor Stand 60 and 72 Models