SEZ SERIES COUNTERTOP STEAMERS INSTALLATION
OPERATORS MANUAL 1183437 PAGE 7
INSTALLATION
Step 2: Installation
1. Uncrate carefully. Report any hidden d amage to the freight carrier IMMEDIATELY.
2. Do not remove any tags or labels u ntil unit is installed and working properly.
3. If unit is to be installed on legs , locate legs and install as shown in Figure 2 belo w.
Figure 2
4. If the unit is to be installed on a cou nter t op or oth er sur f ac e with out us in g legs , th e u nit m ust be sealed
to the surface to prevent any water, grease, etc., from acc umulating under the s teamer. The st eamer
can be bolted to the counter but will still have to be sealed. T he installer may use G.E. or Dow
Corning RTV type sealant. Consult local code for exact requ irements. See Figure 3 on next page.