Southbend SEZ/3 manual Service Request Light Comes On During Operation, Ok?

Models: SEZ/3

1 52
Download 52 pages 24.33 Kb
Page 22
Image 22

TROUBLESHOOTING

SEZ SERIES COUNTERTOP STEAMERS

“Service Request” Light Comes On During Operation

“Service Request” light comes on during operation.

Turn unit off and check that unit drains fully.

Open door. Turn unit back on and wait 20 minutes.

Is water level

Yesat normal level in cavity?

DISCONNECT POWER AT CIRCUIT BREAKER.

Check high-limit thermostats (see Figure 18 on page 35).

No

Check for adequate water pressure to unit.

DISCONNECT POWER AT CIRCUIT BREAKER.

Check controller (see Figure 15 on page 32).

 

High-limit

 

 

 

Yes

 

No

 

thermostats

 

 

 

 

 

 

 

OK?

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace high-limit

thermostats

as necessary.

Check controller (see Figure 15 on page 32) and

replace as necessary.

Yes

Controller OK?

No

Replace controller.

Check water solenoid (see Figure 16 on page 33).

Yes

Water solenoid OK?

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace

water solenoid.

TROUBLESHOOTING

Remove screen from strainer and clean or replace as necessary. Reassemble, reconnect, and recheck the steamer. If the Service Request light still comes on, examine the following for obstructions or deposits: pressure regulator, solenoid, and check valve. Clean or replace as necessary.