TROUBLESHOOTING | SEZ SERIES COUNTERTOP STEAMERS |
“Service Request” Light Comes On During Operation
“Service Request” light comes on during operation.
Turn unit off and check that unit drains fully.
Open door. Turn unit back on and wait 20 minutes.
Is water level
Yesat normal level in cavity?
DISCONNECT POWER AT CIRCUIT BREAKER.
Check
No
Check for adequate water pressure to unit.
DISCONNECT POWER AT CIRCUIT BREAKER.
Check controller (see Figure 15 on page 32).
|
|
|
| ||
Yes |
| No |
| ||
thermostats |
|
|
| ||
|
|
| |||
| OK? |
|
|
| |
|
|
|
| ||
|
|
|
|
|
|
Replace
thermostats
as necessary.
Check controller (see Figure 15 on page 32) and
replace as necessary.
Yes | Controller OK? | No |
Replace controller.
Check water solenoid (see Figure 16 on page 33).
Yes | Water solenoid OK? |
|
| No |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Replace
water solenoid.
TROUBLESHOOTING
Remove screen from strainer and clean or replace as necessary. Reassemble, reconnect, and recheck the steamer. If the Service Request light still comes on, examine the following for obstructions or deposits: pressure regulator, solenoid, and check valve. Clean or replace as necessary.