TROUBLESHOOTING

SEZ SERIES COUNTERTOP STEAMERS

Unit Not Heating Up Properly or Not Cooking Properly, “ON” Light Lit

Unit not heating up properly or not cooking properly, “ON” light lit.

DISCONNECT POWER AT THE CIRCUIT BREAKER.

Check all three main fuses; replace as necessary (see Figure 9 on page 26).

Reconnect power to unit.

Turn unit on. WAIT 5 MINUTES.

Open door; depress and hold door switch.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does contactor

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

“click” on and stay on

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for at least 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

minutes?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DISCONNECT POWER AT CIRCUIT BREAKER.

 

 

DISCONNECT POWER AT CIRCUIT BREAKER.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove control panel.

 

 

 

 

 

 

 

 

 

 

 

 

Remove control panel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check door switch for continuity (see Figure 13 on

 

 

Check resistance between contactor terminals and

 

 

 

 

 

page 30).

 

 

 

 

 

 

 

 

 

replace elements as necessary (see Figure 8 on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

page 25).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Continuity?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace door switch.

Reconnect door switch

lead wires.

Remove rear cover.

Check pressure switch for

proper operation (see Figure 17 on page 34).

No

 

Pressure switch OK?

Yes

 

 

 

 

 

Check high-limit thermostats (see Figure 18 on page 35).

TROUBLESHOOTING

Replace pressure switch.

No

Replace high-limit

thermostats

as necessary.

High-limit

thermostats Yes OK?

Check and replace

contactor (see Figure 11

on page 28) and/or

controller (see Figure 15

on page 32), as necessary.

PAGE 20

OPERATORS MANUAL 1183437

Page 20
Image 20
Southbend SEZ/3 manual Troubleshooting