STRATOSTEAM COUNTERTOP STEAMER

SERVICE

Figure 14

Heating Cartridge Check (at Contactor)

L1

L2

L3

Top of

 

 

 

 

 

 

Steamer

Ohms

A B C

1.DISCONNECT POWER AT CIRCUIT BREAKER.

2.Turn Control Lever to OFF.

3.Remove right side panel of steamer.

4.DO NOT DISCONNECT HEATING-CARTRIDGE LEAD WIRES FOR THIS TEST.

5.Using a multimeter, check the resistance across contactor terminals as specified in the following table:

Serial-

 

 

Model STRE-3D

 

 

Model STRE-5D

 

 

Allowable Resistance (Ohms)

 

Allowable Resistance (Ohms)

 

Plate

 

 

 

 

Three-Phase

 

 

Single-Phase

Three-Phase

 

 

Single-Phase

Voltage

 

 

 

 

 

 

A-B and B-C

A-C

 

A-C

A-B and B-C

A-C

 

A-C

208

10

to 12

14

to 16

 

5 to 6

8 to 10

11

to 13

 

4 to 5

220

12

to 13

15

to 18

 

6 to 7

9 to 11

13

to 15

 

5 to 6

240

14

to 16

18

to 21

 

7 to 9

11 to 13

15

to 17

 

6 to 7

480

55

to 64

73

to 85

 

29 to 34

45 to 52

60

to 70

 

24 to 28

6.If the measured resistance at the contactor is not in the specified range, disconnect all the heating cartridges from the contactor. Measure the resistance across the leads each cartridge. Replace any cartridge that shows either an open or short circuit.

OWNERS MANUAL 1185184

PAGE 25 OF 48

Page 25
Image 25
Southbend STRE-3D owner manual Heating Cartridge Check at Contactor, Disconnect Power AT Circuit Breaker