STRATOSTEAM COUNTERTOP STEAMER

 

SERVICE

Figure 16

 

 

 

Contactor Check

 

 

 

Top of

 

 

 

Steamer

 

 

 

L1

L2

L3

Ohms

 

Actuator

 

 

No Continuity

Button

 

 

 

 

 

A

B

C

View Looking Down

 

 

 

 

 

 

Behind Contactor

1.DISCONNECT POWER AT CIRCUIT BREAKER.

2.Remove right side panel.

3.Depress actuator on top of contactor. Actuator should travel freely and spring back when released.

4.Check for continuity between contacts L1 and A as shown above. There should be no continuity.

5.Repeat Step 4 for contacts L2 and B and for contacts L3 and C.

6.Remove wires B3 and B9 from contactor coil.

7.Place test leads on contactor coil terminals as shown in “View Looking Down” shown above and check resistance

8.If resistance is not in the range 350 to 425 ohms, replace contactor.

9.Reconnect all wires.

OWNERS MANUAL 1185184