SERVICE

STRATOSTEAM COUNTERTOP STEAMER

Figure 19

 

High-Limit Thermostats Check

 

 

Continuity

1.Allow cavity bottom to cool before performing this test.

2.DISCONNECT POWER AT CIRCUIT BREAKER.

3.Remove left side panel.

4.Disconnect wire B4 from left (as shown above) high-limit thermostat.

5.Disconnect wire B5 from right high-limit thermostat.

6.Disconnect remaining high-limit thermostat wires B11 and B12.

7.Test each high-limit thermostat for continuity (as shown above). There should be continuity when the thermostat is cool. Replace as necessary.

8.Reconnect wires.

PAGE 30 OF 48